3.0 Setup
Figure 3-6, Current Flow – Inverter Mode
I/C Amps (MS-PAE, MS-PE and MSH inverter models only):
This menu
displays the inverter or charger amps and is shown as an AC value. A negative
(–) amps reading indicates the inverter is powering the inverter loads, and
the batteries are discharging (inverter amps). A positive (+) amps reading
indicates the inverter is using the AC input source to charge the batteries
(charger amps).
AC Input (MSH inverter models only):
This menu displays the RMS value
of the AC voltage at the inverter’s AC1 and NEUTRAL input terminals.
AC2 Input (Dual Source Inverter models only):
This menu displays the
RMS value of the AC voltage at the inverter’s AC2 and NEUTRAL input terminals.
Info:
If the
AC2 Input
menu displays voltage (~ 50v), but the
generator is off or nothing is connected to the AC2 input; this is
normally because the neutral-to-ground bond connection in the
electrical system is not correct or not connected.
• METER: 02 BM: SOC
thru
06 BM: TECH
– These menus allow the
optional ME-BMK (Magnum Energy’s Battery Monitor Kit)—if installed—to be
con
fi
gured to your speci
fi
c system preferences, and displays the status of
the battery system.
Info:
Refer to Section 8.0 (in this manual) and to your ME-BMK/
BMK-NS Owner’s Manual (PN: 64-0013) for detailed information on
these menus and the Battery Monitor Kit.
Example below:
Current to inverter input (Input Amps) = 0 Amps AC
Current from battery (I/C Amps) = -10 Amps AC
Current to power the AC loads (Load Amps) = 10 Amps AC
MAGNUM
INVERTER
Input Amps =
0 Amps AC
A
Load Amps =
10 Amps AC
I/C Amps =
-10 Amps AC
A
Inverter
Amp meters
=
A
A
AC CURRENT
(GRID/GEN)
DC CURRENT
(BATTERY)
INVERTER
AC LOADS
-120ADC
.
FROM
BATT
0AAC
FROM
GRID
10AAC
TO
LOADS
Current from the battery is used by the inverter
to power the inverter’s AC loads.
[
Status/Fault
]
Input Amps: 0AAC
[
Status/Fault
]
I/C Amps: -10AAC
[
Status/Fault
]
Load Amps: 10AAC
INVERTER MODE