Chapter
5
Commissioning
Important: These procedures must be carried out for the initial start-up of a new system. Failure to follow these
instructions can lead to System and component damage.
Check the Installation
Verify that the System has been installed properly, based on the checkpoints below. In addition, complete the
New
System Initial Readings Form
on page 98 and retain it with your Owner's Manual.
Remember: Damage caused to the system due to operation of an improperly installed system is the liability
of the Installer and the Operator, and is not covered by the Sea Recovery Corporation warranty.
• Check each water connection to the System to ensure that the Installer has properly connected and routed each
tube. Improper routing and/or line blockage will cause System damage. Improperly connected and/or loosely
connected lines that result in leaks and/or damage are the liability of the Installer and the Operator, and are not
covered by the Sea Recovery Corporation warranty.
• Do not assume and do not rely on the Installer’s word; check the System installation yourself.
• Ensure that the Electrical Power Source and the ship's System circuit breaker is switched OFF position.
• Open the Electrical Control Box and verify all electrical and electronic connections. Check for proper wiring and
attachment. After checking all wiring for proper attachment, close the Electrical Control Box.
• Switch the Electrical Power Source and the ship’s System circuit breaker to the ON position.
Check RO Membrane(s)
Important: At times, Sea Recovery Corporation will ship an Aqua Matic RO Desalination System WITHOUT
an RO Membrane Element installed. This is for the purpose of accommodating ship builders who want to
install the System in advance of commissioning the ship.
Verify that the RO Membrane Element(s) have been installed properly within the Pressure Vessels. If the RO
Membrane Element has been installed, there will be an RO Membrane Element Serial Number tag attached to the
High Pressure Vessel. If the RO Membrane Element Serial Number tag is missing or does not contain a serial
number and date, then immediately contact the company that sold the System to you, the Installer, or Sea Recovery
Corporation.
Caution: DO NOT attempt to operate the System without an RO Membrane Element installed, otherwise
extensive damage will result. Damage caused to the System due to an incorrectly installed RO Membrane
Element(s) is the liability of the Installer and the Operator, and is not covered by the Sea Recovery Corporation
warranty.
41
Содержание SRC Aqua Matic 1400-2
Страница 2: ......
Страница 3: ...Aqua Matic Compact 450 1800 Owner s Manual Manual PN B651140001 ...
Страница 4: ......
Страница 12: ......
Страница 30: ......
Страница 47: ...Commissioning 45 ...
Страница 48: ......
Страница 49: ...47 ...
Страница 64: ......
Страница 67: ...65 Commissioning ...
Страница 68: ......
Страница 75: ...73 ...
Страница 96: ......
Страница 125: ...123 ...
Страница 134: ......
Страница 137: ...Chapter 10 Appendix 135 ...
Страница 138: ......
Страница 139: ......
Страница 140: ......
Страница 142: ......
Страница 143: ...Single Phase Electrical Motor Wiring 141 Appendix ...
Страница 144: ...Three Phase Electrical Motor Wiring Aqua Matic Compact 450 1800 142 ...
Страница 145: ...Three Phase Transformer Wiring 143 Appendix ...
Страница 146: ...New System Initial Readings Form Aqua Matic Compact 450 1800 144 ...
Страница 147: ...Daily System Readings 145 Appendix ...
Страница 148: ......
Страница 149: ...Chapter 11 Exploded Parts Views 147 ...
Страница 150: ...Pre Installation Matrix Drawings Aqua Matic Compact 450 1800 148 ...
Страница 167: ...3 18 4 5 9 2 1 11 14 10 15 17 16 19 6 7 8 12 13 MEDIA GARNET 8 12 17 POUNDS MEDIA SAND A1000 25 POUNDS 165 ...
Страница 170: ...Aqua Matic Compact 450 1800 168 ...
Страница 175: ...2 8 11 5 10 7 9 3 16 4 15 6 14 13 12 17 22 21 20 19 19 18 24 23 173 ...
Страница 177: ...2 8 11 5 10 7 9 3 6 4 15 12 13 14 19 18 23 24 21 20 17 16 22 175 ...
Страница 179: ...2 4 3 19 15 11 12 9 10 8 14 17 16 10 13 5 6 18 7 21 20 177 ...
Страница 181: ...21 3 2 18 14 10 11 7 16 15 9 12 4 5 17 20 19 8 6 13 179 ...
Страница 183: ...2 4 3 18 14 21 11 9 10 8 13 16 15 10 12 5 6 17 7 20 19 181 ...
Страница 185: ...9 16 3 7 4 5 2 13 12 14 15 17 28 27 19 11 10 6 25 26 23 1 29 8 24 183 ...
Страница 187: ...9 15 3 7 4 5 2 13 12 14 26 25 17 11 10 6 23 24 21 1 27 8 22 185 ...
Страница 189: ...9 15 3 7 4 5 2 13 12 14 26 25 17 11 10 6 23 24 21 1 27 8 22 187 ...
Страница 191: ...25 23 24 9 16 8 22 20 19 3 28 17 14 12 1 2 7 30 11 10 6 21 29 26 13 4 5 18 27 189 ...
Страница 193: ...23 21 22 9 15 8 20 18 17 3 26 14 12 1 2 7 28 11 10 6 19 27 24 13 4 5 16 25 191 ...
Страница 195: ...23 21 22 9 15 8 20 18 17 3 26 14 12 1 2 7 28 11 10 6 19 27 24 13 4 5 16 25 193 ...
Страница 204: ...25 13 17 15 21 14 16 12 22 19 18 10 9 7 5 6 8 26 3 4 20 1 2 24 27 11 23 28 Aqua Matic Compact 450 1800 202 ...
Страница 212: ......
Страница 213: ...Chapter 12 Electrical Diagrams Foldouts 211 ...
Страница 216: ......
Страница 218: ......
Страница 219: ......
Страница 220: ......
Страница 221: ......
Страница 222: ......