Troubleshooting
03.00|Clamping device SVP-Mini auto/SVP-RM auto|en
49
Troubleshooting
Fault indications
1 In case of a fault, the pump turns off.
The "Info" LED of the pump and the "Function" LED of the re-
mote control light up red.
On the display a corresponding error code is shown.
Correcting the fault
1 For correcting the fault, see table below.
2 Push "enter" key approx. 1 minute.
Error code is deleted. The system control restarts the system.
3 If the error code still appears after restarting the system, contact
the SCHUNK customer service.
Service tel49-7133-103-2333
Service fax: +49-7133-103-942173
The following error codes give information on the cause of the error
Note/fault
Error-
Symbol
Error-
Code
"Battery sta-
tus" LED
"Info" LED
Boot loader activated
Flashing red
Flashing red
Error during initialisation of the SD
card
Flashing orange
Initialisations OK
Flashing green
Target pressure is not reached after
maximal time has passed
1 *
Flashing red
Operating value in red area
2
Flashing red
Battery tension low
3
Flashing red
Operating value in yellow area
Flashing red
Operating value in green area
Flashing green
Maintenance is due
Flashing
red/green
SD card error
Flashing orange
Error during initialisation of sensor
temperature
4
Flashing red
7