Troubleshooting
50
03.00|Clamping device SVP-Mini auto/SVP-RM auto|en
Note/fault
Error-
Symbol
Error-
Code
"Battery sta-
tus" LED
"Info" LED
Overload
5
Flashing red
Machine too cold (continuous con-
trol)
6
Flashing orange
Machine too hot (continuous control)
7 *
Flashing orange
Drop in pressure during compression
8
Flashing red
Fan is not working
9
Flashing red
Control of battery discharge (check
battery)
10
Flashing red
Low tension of 3.3 V
11
Flashing red
Pressure sensor error; pressure below
calibration value of 0 bar
12
Flashing red
I-Fuse error. Shunt/fuse is blown or
motor is running without activation
13
Flashing red
*
For solutions see following table
Error code
Error
Solution
1
Oil level is too low.
1 Depressurize pump.
2 Switch off pump.
3 Uncouple hydraulic hose and connection
cable of the remote control.
4 Turn the pump that the oil filler screw points
to the top.
5 Open oil filler screw and fill in oil up to the
6 Close oil filler screw.
Pump looses oil.
1 Switch off the pump immediately.
2 Send the pump to SCHUNK.
7
Air filter is contaminated. 1 Send the pump to SCHUNK.