5.7.3 Mounting inductive proximity switch IN 50
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
Mount sensor on the version "without adapter plates"
using the inductive proximity switch IN 50, the presence of the
clamping pin in the pallet adapter will be queried.
Ø
Remove the set-screw (33).
Ø
Screw in sensor (2).
Ø
Set switching point so that the proximity switch switches when
the pallet is present.
Ø
Secure sensor using the counter nut (3).
Ø
Adjust sensor, see Sensor Assembly and Operating Manual.
Ø
Query "clamping pin present" position and test functionality.
NOTE
The switching point of the proximity switch must be set so that
the signal that the clamping pin has been detected only comes
when the clamping pin is completely in the locking area.
Mount sensor on the version "with adapter plates"
When using adapter plates, the presence of the pallet adapter is
queried.