KC9111/KC9111-2 & KC9321/KC9321-2 INSTALLATION
Test Operation
57040-E Page 25 04-2007
Test Operation
Test Operation:
1.
For KC9111/KC9111-2:
Lever should be able to be pushed down, but not up.
> If you find that this is not correct, see,
Verify Lever / Turnpiece Stop Screw Direction:
on page 12
2.
For KC9321/KC9321-2:
Turnpiece should rotate clockwise for Right Hand/Right Hand Reverse and
counterclockwise for Left Hand/Left Hand Reverse.
> If you find that this is not correct, see,
Verify Lever / Turnpiece Stop Screw Direction:
on page 12
3. Insert key into cylinder and rotate it counterclockwise.
> Lever/turnpiece should retract latch.
NOTE: The key should only rotate counterclockwise, not clockwise. If you find that this is not
correct, see,
Partially Tighten the Set Screw: on page 11
.
4. Rotate key back to original position and remove it.
> Lever/turnpiece should no longer retract latch.
5. Using the keypad, enter the default access code: 1 3 5 7 9.
•
The red LED should light each time the first four numbers are pressed and when the 9 is
pressed, the green LED should flash for five seconds during which time the lever/turnpiece
should retract the latch.
6. Test inside egress device (paddle/exit device, etc.) to make sure it is properly operating.
SEE PROGRAMMING GUIDE FOR PROGRAMMING INFORMATION