background image

P:\INST INSTRUCTIONS\BOLT LOCKS\INST-2490A       REV C       10-21       Page 1

2490A

EXTRA NARROW CONCEALED MORTISE BOLT LOCK

FAIL-SECURE

Any suggestions or comments to this instruction or 

product are welcome.  Please contact us through 

our website or email [email protected] 

Easy installation or servicing

All Space Saver locks

are easily installed in

any existing entrance

merely by mortising out

a cut-out, attaching the

wiring, inserting the 

lock, and bolting it into

position with two

attaching tabs.  Cutting

studs is no longer a

problem or expense.

OVERHEAD INSTALLATION HORIZONTAL

1. Examine the top rail of the door for the most suitable location for the strike plate. Mark the door for the end of the strike closest to 

the lock stile, and make a corresponding mark on the header to line up with the first mark.

2. Locate center line of door thickness on the header and attach adhesive cut out template to header. Lining it up with marks, center 

punch the tab-mounting screw locations and counter-sink for #10 screw. Saw or rout out the cutout area.  Continue to step 5.

SIDEJAMB INSTALLATION VERTICAL

3. Examine the lock stile jamb for the point nearest the center of the door height, with space available for the lock and strike. Mark 

the door stile horizontal for the top end of the strike plate and make a corresponding mark on the jamb.

4.  Locate center line of door thickness on the jamb and attach adhesive cutout template to jamb, lining up the the top of the cutout 

with the horizontal mark on the jamb. Center punch the tab mounting screw locations and counter sink for #10 screw. Saw or rout 

the frame cutout.

5.  Attach the mounting tabs inside.

6. Attach power supply and access control leads to lock leads as shown on page 2. Handle the lock carefully; do not hang it by the 

wire leads. Insert wiring into the header cavity carefully so they do not interfere with proper locating of the lock in the cutout.

7. Insert lock. When installed overhead horizontally, the bolt end is nearest the lock stile. When installed vertically on the sidejamb, 

the bolt must be at the top end of the cutout.  Secure with #10-32 machine screw.

8. Using strike plate as a template, mark screw hole location and drill holes for screws supplied. Mortise as required. Attach strike.
9. The Automatic Relock Switch (ARS) is set for 1/8” clearance between the top of the door and transom bar or head jamb. Any 

additional gap may be compensated for by loosening the lock nut and turning the switch assembly clockwise until proper 

adjustment is reached. Be sure to tighten lock nut when adjustment is satisfactory.

Fig. 2

Auto Relock Switch (ARS)

Adjustable for Wide Door Gap

Loosen nut.

Turn assembly 

clockwise for wide 

door gap.

Tighten nut.

Fig. 1

SECURITY DOOR CONTROLS   ■   WWW.SDCSECURITY.COM

[t] 800.413.8783  ■  805.494.0622  ■  E-mail: [email protected]  ■  801 Avenida Acaso, Camarillo, CA  93012  ■  PO Box 3670, Camarillo, CA  93011

INSTALLATION INSTRUCTIONS

2.  Position screws

     for attaching tabs,

     drill holes, attach tabs.

1.  Mortise cut-out in 

     tube for face plate

     (fits flush with

     surface of tube).

3.  Connect wiring

     to lock.

4.  Slide lock into

     position, attach

     to tabs.