External Interlock Connector
It is possible to connect all the emergency devices aimed at making the laser source safe, in
series with this connector.
Pin N°
Signal
Description
Status
1 (+)
Potential free
contact
2 (return) Potential free
contact
INTERLOCK
Open contact = Emergency
Enabled
3
0 V
GND
N.B.: If the emergency is enabled by opening the Interlock contact it cannot be reset.
Resetting is only possible by putting the main switch MS in the Open position (
O
) and then
the closed positions (
I
).
Galvo Supply Connector
Pin N°
Signal
Description
Status
1–6-2 (-)
- 15 V
NEGATIVE SUPPLY
Negative power supply -15V / 3°
max
7–3–8 (0)
0 V
COMMON
Common
4–9-5 (+)
+15 V
POSITIVE SUPPLY
Positive power 15V / 3°
max
Slave Out Connector
Picture 16: Slave Out Connector (15p / f)
Picture 14: External Interlock connector (3p / f)
1
2
3
Picture 15: Galvo Supply Connector (9 p /m)
8 7 6 5 4 3 2 1
15 14 13 12 11 10 9
1 2 3 4 5
6 7 8 9