The rear management panel faces the side opposite the operator and includes the following
elements:
1 Socket for 230/110 Vac – 3/6A – 50/60Hz mains supply
2 Main
switch to disconnect from the mains
3 Protection
fuses (5x20mm, 6.3A/250V type T)
4 Galvo
Supply
connector (sub-D, 9 p., male) for Scanner Head power
5
Internal Interlock Connector (DIN, 3 p., male) for connection to an external
emergency interlocks circuit.
6 Aiming
Beam connector (SMB, female) for connecting the red aiming diode.
7
Command Box connector (sub-D, 25 p., female) for connection to an external
command box.
8
P.C. connector (sub-D, 9 p., female) for connecting the device to the DSp2 contained
in the external Personal Computer.
9
Slave Out connector (sub-D, 15 p., female) (not used in this version).
10 Optical Fibre connector (D-80-LKA) for the optical fibre connection between the
Rack and Resonator.
11 R.F. connector (not used in this version).
12 Cooling fan