Schilling Marking Systems GmbH
In Grubenäcker 1 DE-78532 Tuttlingen
+49 (0)7461 9472-0
+49 (0)7461 9472-20
www.schilling-marking.de
MegaLight
Installation
Technical modifications reserved
31
Edition 2004
4.
Enable the ELECTRONIC SHUTTER, closing the contact between pin 07 and 08 of the
COMMAND BOX connector (7) located on the rear Management Panel of the power
supply box (see Appendix B. Wiring and connection diagrams).
Make sure that the following events occur:
•
RED led on: READY condition
•
The aiming red diode disappears from the beam
5.
Disable the ELECTRONIC SHUTTER, reopening the contact between pin 07 and 08 of the
COMMAND BOX connector (7) located on the rear Management Panel of the power
supply box (see Appendix B. Wiring and connection diagrams).
Make sure that the following events occur:
•
ORANGE led on: return to STANDBY condition
•
The aiming red diode reappears at the beam
N.B.: once this hardware start-up phase is finished, the laser source is in the condition to
accept the ENABLE command and pass from STANDBY to READY and ready to operate.
Start-up procedure (Software)
1.
Start the Personal Computer where the DSP2 board has been installed on the P.C.I. Bus
following the instructions in the Smartist4 Manual.
2.
Install the Smartist4 engraving software.
3.
Follow the instructions for starting the software and engraving contained in the
Smartist4 Manual.
4.
Carry out the start-up procedure to bring the device to READY condition.
WARNING:
From this point on the source is ready to emit laser radiation for the Resonator or
engraving head, if connected.
5.
Select an engraving file and then give the START ENGRAVING command.
6.
Effect a few engravings to make sure the device is operating correctly.