Schilling Marking Systems GmbH
In Grubenäcker 1 DE-78532 Tuttlingen
+49 (0)7461 9472-0
+49 (0)7461 9472-20
www.schilling-marking.de
MegaLight
Installation
Technical modifications reserved
57
Edition 2004
DESCRIPTION
VIOLINO EUMARKER EXTERNAL WIRING
REVISED
REL. 03
110-230Vac/50-60 Hz
External Interlock
Command Box
Slave out
P.C.
Galvo Supply
R.F.
Aiming Beam
L1
L2
PE
External back-up fuses 16A gG /gL
G1
0V
15V
Line Filter (leakage 0.42 mA)
6.3A - F
3
2
1
+12-15V
2.2k
U12A
Remote External Interlock
(potential free N.C.contact)
SB4
+12V
TLP521
2.2k
U12B
1
2
SB1
Remote Emergency STOP
(potential free N.C.contact)
1
2
1
2
4
2.2k
U12D
12
SB2
Remote START
(potential free manteined
contact . KEY-SWITCH)
4
12
0 I
7
2.2k
U12C
8
SB3
Remote STAND-BY/READY
(potential free make contact)
7
8
18
19
+12V
U25
20
21
TLP523
+12V
U23
+12V
U24
22
24
19
18
21
20
22
24
KA1
KA2
KA3
Laser POWER ON
(12V-50mA; active=Power ON)
Laser NOT READY
(12V-50mA;active=Laser not Ready)
Laser ENABLE
(12V- 50mA;active=shutter opened)
+12V
+24V
max.200mA
NOT USED
NOTE: do not use others pins
internally connected!
Use only original cable.
Max.wiring distance < 3m.
(15m with twisted and shielded
cable submitted to approval)
CNY17-3
U8
2
6
6N137
0.36k
0.36k
0
-
+
0
LM324
1
3
8
+12V ext
0V ext
0-10V
Power level signal
(analog 0-10V)
8
L - H
2
1
0V ext
+12V ext
3
Pen-Up
(digital signal)
External DC supply
(12V - 50 mA)
0V
-15V
+15V
1
6
2
7
3
8
4
9
5
External P.C.Command
Marking Head
Galvo supply
(+/- 15V-3A)
U17
R.F.Driver
Red Aiming Beam
Laser
(5V -50mA)
Not used
A.C.Supply
1
6
2
7
3
8
4
9
5
-
0
+
Y
X
G2
DWG n°
E203AL004
5.6k
HCPL7800