MegaLight
Installation
Technical modifications reserved
29
Edition 2004
3.
Slide the optical fibre into the spring mounted grommet in the back cover.
4.
Remove the protection cap from the fibre socket located on the rear wall of the
Resonator.
5.
Referring to Fig. 12: Optical fibre connector, remove the protective cap (1) of the
optical fibre connector, by unscrewing nut (4).
6.
Insert the optical fibre connector in the fibre socket present on the rear wall of the
Resonator:
- gently place the optical fibre connector on the fibre socket
- carefully insert the optical fibre connector, making absolutely certain that the
optical surface of the fibre connector (2) does not come into contact with any
other surface.
WARNING:
The operation for inserting the fibre needs to be carried out very carefully.
Absolutely avoid letting the optical surface of the fibre connector come into
contact with any other surface.
Contact of the fibre optical surface with any other surface may damage it.
7.
Make sure the mechanical supports (3) on the male/female connectors are in the
correct position.
8.
Screw down nut (4) on the Resonator fibre socket connector.
9.
Screw down the rear cover on the Resonator again.
N.B.:
Keep the protection caps for the optical fibre and fibre socket. Returns of optical
fibres or resonators without these caps will not be accepted.
WARNING:
The optical fibre must never be subject to curve radii under 15 cm. to prevent
damaging it or breaking it.
WARNING:
The optical fibre is an integral part of the laser engraving system.
Do not work with the optical fibre disconnected or damaged.
Using an optical fibre which is greatly bent, damaged or poorly connected may lead
to a serious optical risk.