20 Technical data
Operating Manual 90° ACTUSAFE CMF(S)QT
OM-ENGLISH-Failsafe-QT-16xx-V2.00-2022.03.01
20.9
Mode of operation CM03 + L
ON-OFF & INCHING operation
CM03 + L50
CM03 + L100
CM03 + L350
S2 - 15 minutes according to IEC
60034
S2 - 15 minutes according to IEC
60034
S2 - 15 minutes according to IEC
60034
2,5 - 72 RPM
2,5 - 60 RPM
2,5 - 60 RPM
F
max
= 15 kN
F
max
= 25 kN
F
max
= 26 kN
F
avg
= 7,5 kN
F
avg
= 10 kN
F
avg
= 10 kN
Life time*
10.000 cycles
10.000 cycles
10.000 cycles
MODULATING operation
CM03 + L50
CM03 + L100
CM03 + L350
S4 - 1.200 c/h - max. 50% DC
according to IEC 60034
S4 - 1.200 c/h - max. 50% DC
according to IEC 60034
S4 - 1.200 c/h - max. 50% DC
according to IEC 60034
2,5 - 36 RPM
2,5 - 30 RPM
2,5 - 30 RPM
F
max
= 15 kN
F
max
= 25 kN
F
max
= 26 kN
F
avg
= 7,5 kN
F
avg
= 12,5 kN
F
avg
= 13 kN
Life time*
1.800.000 starts
1.200.000 starts
1.200.000 starts
CONTINUOUS MODULATING operation
CM03 + L50
CM03 + L100
CM03 + L350
NOT AVAILABLE
NOT AVAILABLE
NOT AVAILABLE
*
NOTE:
life time is based on proper operation and maintenance according to SCHIEBEL operating manual
CYCLE
= stroke of 40 mm in both directions with at least 30% of nominal toque and the ability to accept 100% of nominal
torque for at least 5% of the stroke
START
= movement of at least 1% of stroke in both directions with a load of minimum 30% of nominal torque
90