SCAIME Manual : NU-eNod4C-E-0418-196712-F.docx
•
Window
11.2.3
Motion:
The outputs can be assigned to copying measurements stability.
11.2.4
Defective measurement:
The output level is set when the internal alarm flag described in “Weighing diagnosis” § in the MEASUREMENT AND
STATUS § is activated. This allows to warn about defection of the measurement chain. Checkweigher alarms are not
considered as defective measurements
11.2.5
Input image:
Outputs can be assigned to copying inputs state, either using the same logic or inverting the input state (negative logic).
Outputs 1 and 3 can be assigned to input 1 and outputs 2 and 4 to input 2.
11.2.6
Level on request:
Activation of outputs is triggered by master requests. When an ‘
output activation
’ command is received.
11.2.7
Cycle in progress:
See checkweigher operating mode.
11.2.8
Checkweigher result available:
See checkweigher operating mode.
11.2.9
Checkweigher result out of tolerances:
Fig. 11
Functioning in hysteresis
Fig. 9
high
val.
t
output
low
val.
Functioning in window
Fig. 10
high
val.
t
output
low
val.