SCAIME Manual : NU-eNod4C-E-0418-196712-F.docx
Parameter
Possible Value
Description
Calibration Parameters
Range
0
–
10 000 000
Maximum weighing capacity
Division
1, 2, 5, 10, 20, 50
Difference between two consecutive indicated values
Decimals
0-7
Position of decimal point
Weight unit
4 visible char
Weight measurement unit (g, kg, t, lb…) using for
calibration
Time unit
s, mn, h
Time unit using for calibration (eNod4-F and B). Only s and h can
be selected in eNod4-B.
Weight unit (display
flow rate)
g, kg, t
Weight unit of flow rate which is displayed on main screen.
Time unit (display
flow rate)
s, mn, h
Time unit of flow rate which is displayed on main screen.
Cut-off frequency
(display flow rate)
Cut-off frequency of flow rate which is displayed on main
screen.