36
SCAIME Manual : NU-eNod4C-E-0418-196712-F.docx
11
OUTPUTS FUNCTIONING
Each output can be individually set to positive or negative logic.
11.1
Outputs assignment:
Function
Functioning mode
transmitter
checkweigher
None
●
●
Set point
●
●
Motion
●
●
Defective measurement
●
●
Input image
●
●
Level on request
●
●
Cycle in progress
●
Checkweigher result available
●
Checkweigher result out of tolerances
●
Checkweigher result within tolerances
●
Checkweigher result out of high tolerance
●
Checkweigher result out of low tolerance
●
11.2
Description:
11.2.1
None:
The output has no function
11.2.2
Set point:
The outputs can be assigned to configurable set points. Output 1 is assigned to set point 1, output 2 to set point 2 and
so on.
Set points can be assigned to:
•
gross measurement
•
net measurement
•
Checkweigher result
•
Checkweigher total running
Set points and are defined by a high value, a low value and a functioning mode.
Two functioning modes are possible:
•
Hysteresis
Содержание eNod4-C BOX
Страница 8: ...8 SCAIME Manual NU eNod4C E 0418 196712 F docx 3 GENERAL CHARACTERISTICS 3 1 Dimensions ...
Страница 9: ...9 SCAIME Manual NU eNod4C E 0418 196712 F docx ...
Страница 14: ...14 SCAIME Manual NU eNod4C E 0418 196712 F docx 4 CONNECTIONS ...
Страница 64: ...64 SCAIME Manual NU eNod4C E 0418 196712 F docx Parameter Possible Value Description Metrology Parameters ...