Model 466-1 Adapter
Common Procedures And Programming Sequences 65
Chapter 8: Common Procedures And Programming
Sequences
8.0 Introduction
Chapter 8 includes information about common procedures and programming
sequences.
Before proceeding, please become familiar with the contents of Chapters 6
and 7.
8.1 Adapter Initialization And Testing
1.
Read the Local Status Register and ignore the data. This awakens the
adapter.
2.
Read the Remote Status Register and ignore the data. This clears any
incomplete transactions in the cable buffers.
3.
Write
0x80
to the Local Command Register. This resets any false status
bits that may have been set during the power on transition.
4.
Read the Local Status Register. The contents of the Local Status Register
are now valid and no error bits should be set.
After the initialization and testing sequence is complete, about 50% of the
adapter has been used. The remaining 50% involves Direct and Page
Mode accesses to remote VMEbus RAM, Dual Port RAM, and interrupts.
Содержание 466-1
Страница 1: ...Model 466 1 Adapter Hardware Manual Connects a SBus Computer to a VMEbus System...
Страница 2: ...Model 466 1 Adapter ii...
Страница 24: ...Model 466 1 Adapter 14 Adapter Functions...
Страница 52: ...Model 466 1 Adapter 42 VMEbus Adapter Card Configuration...
Страница 70: ...Model 466 1 Adapter 60 CSR Accessed From The SBus...
Страница 88: ...Model 466 1 Adapter 78 Common Problems And Solutions...
Страница 106: ...Model 466 1 Adapter 96 Jumper Configuration Worksheets...
Страница 107: ...Model 466 1 Adapter Jumper Configuration Worksheets 97 D 1 SBus Adapter Card Worksheet J1...
Страница 108: ...Model 466 1 Adapter 98 Jumper Configuration Worksheets...
Страница 110: ...Model 466 1 Adapter 100 Jumper Configuration Worksheets...