GROUP S.P.A.
MT SBC 01
18
4B-2) DISPLAYING THE AUDIO TIMING, DOOR LOCK RELEASE TIME AND RESET
WAIT TIME FOR THE PORTER MODULE
This operation enables you to display the audio timing, door lock release relay closure
time and reset wait time for the porter module.
INITIAL CONDITION
Configuration mode has
been accessed
(see point 4A).
Porter module Art. 3062 /
3262/ 3268 powered
with terminal PR connected
to the - terminal.
Select the SETTINGS/
SYSTEM PAR. /
PORTER / VIEWING menu
with the
.
To exit the menu,
press
X
.
When you have made the
change, remove the
connections between PR and
– on the terminals of porter
module 3062 / 3262 / 3268.
The module is in
programming mode:
The menus are scrolled
through automatically
every 2 seconds.
The module is in
programming mode.
After 3 seconds, the values
of the other parameters are
displayed in sequence.
MAIN
SETTINGS
AUDIO TIMING
VALUE: 180
DISPLAY
DESCRIPTION
OPERATION
*
N.B: The values in
brackets are the min and
max limits of the
parameter
(ref. table page 21).
If entry is successful.
If entry does not fall within
the limits.
DISPLAY
DESCRIPTION
OPERATION
DOWNL. MODE ( 0 -1 )
*
VALUE: _
PARAMETER
CHANGED
Or:
ENTRY
WRONG
Select the SETTINGS/
SYSTEM PAR./
TYPE OF DOWNLOAD
menu using the
. To
cancel an operation or exit
the menu, press
X
.
Enter the desired value
for the parameter.
Press
to confirm the value
of the parameter.
4B-3) TYPE OF SERIAL DOWNLOAD
The parameter sets the type of connection used for downloading the list used for
managing INDIRECT CODE mode.
Either an RS232 or RS485 interface is available.
INITIAL CONDITION
Configuration mode has
been accessed
(see point 4A).
The module is in
programming mode.
The menus are scrolled
through automatically
every 2 seconds.
MAIN
SETTINGS
The list with the listed fields can only entered by means of software Art. 1249/A set to
INDIRECT CODE mode without Name field.
4B-4) CALL MODE
The parameter sets the operating mode of the call module as STANDARD or INDIRECT
CODE.
STANDARD CALL MODE (factory-set):
In this operating mode, the interphone user is identified by a
Code
.
The call is made as follows:
• From the keypad, key in the code 1
➔
and press
. to send the call to the user identified
by code 1.
INDIRECT CODE CALL MODE:
In this operating mode, the interphone user is identified by the
Indirect Code
and
Code
fields.
EXAMPLE: User
John Smith
identified by Code = 1 and Indirect Code = 100
The call is made as follows:
• From the keypad, key in the
Indirect Code
100
➔
and press
to send the call to
the user identified by code 1.
INITIAL CONDITION
Configuration mode has
been accessed
(see point 4A).
The module is in
programming mode.
The menus are scrolled
through automatically
every 2 seconds.
MAIN
SETTINGS
*
N.B: The values in
brackets are the min and
max limits of the
parameter
(ref. table page 21).
CALL MODE ( 0 -1 )
*
VALUE: _
Select the
SETTINGS/SYSTEM PAR./
CALL MODE menu, using
the .
To cancel an operation or
exit the menu Press
X
.
DISPLAY
DESCRIPTION
OPERATION
If entry is successful.
If entry does not fall within
the limits.
PARAMETER
CHANGED
Or:
ENTRY
WRONG
Enter the desired value
for the parameter.
Press
to confirm the value
of the parameter.
It is possible to change
the audio timing,
door lock release relay
activation time
and reset wait time.
The menus are scrolled
through automatically
every 2 seconds.
*
N.B: The values in
brackets are the min and
max limits of the
parameter (ref. table page
21).
If entry is successful.
If entry does not fall within
the limits.
DISPLAY
DESCRIPTION
OPERATION
PORTER PAR.
ENTER t AUDIO
t AUDIO ( 10-180 )
VALUE: _ _ _
t AUDIO ( 10-180 )
*
VALUE: 100
PARAMETER
CHANGED
Or:
ENTRY
WRONG
Select the
SETTINGS/SYSTEM PAR./
PORTER PAR. menu by
pressing
. To cancel an
operation or exit the menu,
press
X
.
Using the
key, select
the menu option for the
parameter you want to
change.
EXAMPLE:
Changing audio timing.
Key in the desired value.
EXAMPLE:
100.
Press the key
to confirm the value
of the parameter.
When you have made the
change, remove the con-
nections between PR and –
on the terminals of porter
modules 3062/3262 /3268.
4B-5) RS485 ADDRESS
The value of this parameter is used only in special applications.
INITIAL CONDITION
Configuration mode has
been accessed
(see point 4A).
The module is in
programming mode.
The menus are scrolled
through automatically
every 2 seconds.
MAIN
SETTINGS
Содержание MT 01
Страница 17: ...MT SBC 01 15 MT SBC 01 U P yellow green A L T O A L T O MIC U P U P 8 9 10 11 12 13...
Страница 18: ...GROUP S P A MT SBC 01 16 U P UP U P UP ALTO UP 1 2 P U P 14 15 16 SOLUTION A SOLUTION B...
Страница 30: ...GROUP S P A MT SBC 01 28 1 6 7 2 3 4 5 Installation instructions for N AV 4 audio external unit yellow green...
Страница 41: ...MT SBC 01 39 MT SBC 01 2 3 1 6 5 4 6 Mounting the monitor on desktop base Art 5712...