8
8-9. Operating Multiple In/Outdoor Units Simultaneously
(Group Control)
Group control works well for providing air conditioning to one, large
room with more than one air conditioning units.
• One remote control can operate up to eight indoor units.
• All the indoor units have identical settings.
• Set temperature sensing to the indoor unit (Main Sensor).
8-10. Using the Remote Control
• Point the transmitter of the remote control at the receiver. When the signal is received correctly it will beep once.
(It beeps twice only when the unit starts operating.)
• The signal can be received at a distance of about 6 meters. This distance should be used only as a guide. It
depends on battery strength.
• Make sure nothing is between the remote control and the receiver that could block the signal.
• Do not leave the remote in direct sunlight, where the wind from the air conditioner can blow directly on it, or near
any other heat source.
• Take care not to drop, throw or wash the remote control with water.
• The signal from the remote control may not be received in rooms with rapid start fl uorescent lighting, inverter
lights, plasma displays, LCD televisions (monitor), etc. For more information, please contact the dealer where the
product was purchased.
Wall Mount Use
• Press
from the location you wish to mount the remote and make sure the
signal is received correctly.
• Pull the remote control forward to remove it.
8-11. For Best Results
Don’t get the remote control too far away from the receiver.
This may cause a malfunction.
Be sure to keep the remote control in the same room as the receiver.
Point the remote control at the receiver.
When the signal is received correctly it will beep one time.
Avoid locating the remote control where it is covered, such as behind a curtain.
Keep it out in the open.
8-12. Addresses
In both multi and single unit installations,
when more than one indoor unit is installed in the same room with
a compatible remote control, addresses can be set up to avoid crosstalk. By setting the address switches on the
receivers and matching them with the number of addresses on the remote control, up to six indoor units can be
controlled separately with the remote control. (When using units in a fl exible combination or operating multiple units
simultaneously, as they are operated at the same time, they cannot be controlled individually.) There are separate
address settings, receiver addresses for the receivers*
1
and transmitter addresses for the remote control.
For more information, please contact the dealer where the product was purchased.
• The setting procedure is different for Indoor Unit (K type). (See Setting Addresses (K Type) in the next page.)
• These settings are saved in nonvolatile memory in the remote control, so even when its batteries are changed,
the settings do not have to be made again.
*1 RCS-SH80BG.WL and RCS-TRP80BG.WL are of receivers (Inside the indoor unit); RCS-SS80BG.WL is of an
operation panel. (Inside the indoor unit)
Checking Addresses
When you press
on the remote control, its current address is shown in the display. If this address corresponds
to the address of a receiver*
2
, the buzzer sounds. (If it is on ALL, the buzzer will always sound.)
If it is on ALL, it can be operated regardless of receiver addresses. Point the remote control at the receiver you wish
to operate and transmit.
*2 RCS-SS80BG.WL is a receiver. (Indoor unit)
Matching up Addresses
Setting Remote Control Addresses
1. If you press
and
at the same time, “
” will blink.
2. While
holding down, every time you press
, it cycles from ALL
1
2
3...6
ALL.
Set it to the receiver address switch of the indoor unit you wish to operate.
3. When you release
, the address that was displayed is set.
When you do this, if it corresponds to the receiver’s address setting, the buzzer sounds.
Fasten the remote
control mount with
screws.
Fitting the remote
control in the
mount.
Remote control
mount
1
2
Put in
Press
Wireless Remote Control
Signal Line
Indoor Unit
Indoor Unit
Receiver
8-7
SM830160-03̲Classic̲PAC-i̲A4.ind7 7
SM830160-03̲Classic̲PAC-i̲A4.ind7 7
2010/02/16 10:31:16
2010/02/16 10:31:16
Содержание SPW-C256VH
Страница 364: ... MEMO 1 358 ...
Страница 398: ... MEMO 2 34 ...
Страница 402: ...3 4 3 3 1 Indoor Units 4 Way Air Discharge Semi Concealed Type SPW XM125 165 185H Electric Wiring Diagram 䡵 ...
Страница 403: ...3 5 3 3 1 Indoor Units Wall Mounted Type SPW KR124GH56 SPW KR184GH56 Electric Wiring Diagram 䡵 ...
Страница 404: ...3 6 3 3 1 Indoor Units Wall Mounted Type SPW KR124GH56 SPW KR184GH56 Schematic Diagram 䡵 ...
Страница 405: ...3 7 3 3 1 Indoor Units Wall Mounted Type SPW KR254GH56 Electric Wiring Diagram 䡵 ...
Страница 406: ...3 8 3 3 1 Indoor Units Wall Mounted Type SPW KR254GH56 Schematic Diagram 䡵 ...
Страница 409: ...3 11 3 3 1 Indoor Units Concealed Duct Type SPW UR124 164 184 254 364 484 604GH56 A B Electric Wiring Diagram 䡵 ...
Страница 410: ...3 12 3 3 1 Indoor Units Concealed Duct Type SPW UR124 164 184 254 364 484 604GH56 A B Schematic Diagram 䡵 ...
Страница 411: ...3 13 3 3 1 Indoor Units Concealed Duct Type SPW U125 165 185 255 365 485 605H Electric Wiring Diagram 䡵 ...
Страница 412: ...3 14 3 3 1 Indoor Units Concealed Duct Type SPW U125 165 185 255 365 485 605H Schematic Diagram 䡵 ...
Страница 415: ...3 17 3 3 1 Indoor Units Concealed Duct Type SPW US125 165 185H Electric Wiring Diagram 䡵 ...
Страница 416: ...3 18 3 3 1 Indoor Units Concealed Duct Type SPW US125 165 185H Schematic Diagram 䡵 ...
Страница 417: ...3 19 3 3 2 Outdoor Units Electric Wiring Diagram SPW C256VH ...
Страница 419: ...3 21 3 3 2 Outdoor Units Electric Wiring Diagram SPW C366VH ...
Страница 421: ...3 23 3 3 2 Outdoor Units Electric Wiring Diagram SPW C486VH ...
Страница 423: ...3 25 3 3 2 Outdoor Units Electric Wiring Diagram SPW C256 366VH8 ...
Страница 425: ...3 27 3 3 2 Outdoor Units Electric Wiring Diagram SPW C486 606VH8 ...
Страница 472: ... MEMO 6 10 ...
Страница 490: ... MEMO 7 18 ...
Страница 517: ...SANYO Electric Co Ltd Printed in Japan 201002E DC ...