I - 111
SM830082
1
2
3
4
5
1. Specifications
Cooling:
Rating Conditions
: Indoor Air Temperature
80
°
F DB / 67
°
F WB
Outdoor Air Temperature
95
°
F DB
Full Load Conditions : Indoor Air Temperature
80
°
F DB / 67
°
F WB
Outdoor Air Temperature 115
°
F DB
Heating:
Rating Conditions
: Indoor Air Temperature
70
°
F DB / 60
°
F WB
Outdoor Air Temperature
47
°
F DB / 43
°
F WB
Full Load Conditions : Indoor Air Temperature
80
°
F DB / —
°
F WB
Outdoor Air Temperature
45
°
F DB / 35
°
F WB
Indoor model: TH3642 / Outdoor model: CH3642
●
Cooling
●
Heating
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230 - 208 V / 1 phase / 60 Hz
230 - 208 V / 1 phase / 60 Hz
Rating conditions
A
0.7 - 0.7
1.8 - 1.8
12.6 - 13.2
15.1 - 15.7
kW
0.16 - 0.14
0.36 - 0.34
2.83 - 2.69
3.35 - 3.17
Full load conditions
A
0.7 - 0.7
1.8 - 1.8
15.4 - 16.8
17.9 - 19.3
kW
0.16 - 0.14
0.36 - 0.34
3.45 - 3.38
3.97 - 3.86
Starting amperes
A
1 - 1
2 - 2
95 - 86
97.7 - 88.7
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230 - 208 V / 1 phase / 60 Hz
230 - 208 V / 1 phase / 60 Hz
Rating conditions
A
0.7 - 0.7
1.8 - 1.8
15.7 - 17.1
18.2 - 19.6
kW
0.16 - 0.14
0.36 - 0.34
3.43 - 3.41
3.95 - 3.89
Full load conditions
A
0.7 - 0.7
1.8 - 1.8
13.6 - 14.6
16.1 - 17.1
kW
0.16 - 0.14
0.36 - 0.34
3.02 - 2.98
3.54 - 3.46
Starting amperes
A
1 - 1
2 - 2
95 - 86
97.7 - 88.7