I - 52
SM830082
1
2
3
4
5
1. Specifications
Indoor Unit: XH2442
Outdoor Unit: CH2442
• 208V / 1 phase / 60Hz
RATING CAPACITY :
23,400 BTU/h
AIR FLOW RATE:
510 CFM
EVAPORATOR
CONDENSER
ENT.TEMP.
°
F(
°
C)
AMBIENT TEMP
°
F(
°
C)
WB
DB
75
85
95
105
115
(23.9)
(29.4)
(35.0)
(40.6)
(46.1)
TC
23,700
22,560
21,250
19,770
18,140
CI
1.75
1.92
2.09
2.33
2.56
72(22.2)
SHC
16,220
15,570
14,840
14,040
13,190
59
76(24.4)
SHC
17,930
17,280
16,560
15,760
14,910
(15.0)
80(26.7)
SHC
19,730
19,080
18,350
17,550
16,700
84(28.9)
SHC
21,440
20,790
20,060
19,270
18,140
88(31.1)
SHC
23,160
22,510
21,250
19,770
18,140
TC
24,590
23,490
22,320
20,990
19,540
CI
1.77
1.94
2.12
2.36
2.6
72(22.2)
SHC
13,970
13,390
12,790
12,130
11,430
63
76(24.4)
SHC
15,680
15,110
14,510
13,840
13,140
(17.2)
80(26.7)
SHC
17,470
16,900
16,300
15,640
14,940
84(28.9)
SHC
19,190
18,610
18,010
17,350
16,650
88(31.1)
SHC
20,900
20,330
19,730
19,070
18,360
TC
25,530
24,520
# 23,400
22,160
20,800
CI
1.79
1.96
2.14
2.39
2.63
72(22.2)
SHC
11,700
11,220
10,690
10,130
9,520
67
76(24.4)
SHC
13,410
12,930
12,410
11,840
11,230
(19.4)
80(26.7)
SHC
15,210
14,720
14,200
13,630
13,030
84(28.9)
SHC
16,920
16,440
15,910
15,350
14,740
88(31.1)
SHC
18,640
18,150
17,630
17,060
16,450
TC
26,890
25,950
24,940
23,840
22,630
CI
1.81
1.98
2.17
2.42
2.67
72(22.2)
SHC
9,480
9,070
8,640
8,180
7,680
71
76(24.4)
SHC
11,200
10,790
10,360
9,890
9,400
(21.7)
80(26.7)
SHC
12,990
12,580
12,150
11,690
11,190
84(28.9)
SHC
14,700
14,300
13,860
13,400
12,900
88(31.1)
SHC
16,420
16,010
15,580
15,120
14,620
TC
27,420
26,540
25,600
24,520
23,380
CI
1.84
2.01
2.2
2.46
2.71
75
76(24.4)
SHC
8,700
8,360
8,000
7,590
7,170
(23.9)
80(26.7)
SHC
10,490
10,150
9,790
9,380
8,960
84(28.9)
SHC
12,210
11,870
11,500
11,100
10,670
88(31.1)
SHC
13,920
13,580
13,220
12,810
12,390
TC :Total Cooling Capacity (BTU/h)
SHC:Sensible Heat Capacity (BTU/h)
CI :Compressor Input (kW)
Rating conditions are
M.R.=
8.39
USpints/h
:Outdoor Ambient Temp.95
°
FDB
:Indoor Unit Entering Air Temp.80
°
FDB/67
°
FWB