I - 113
SM830082
1
2
3
4
5
1. Specifications
Cooling:
Rating Conditions
: Indoor Air Temperature
80
°
F DB / 67
°
F WB
Outdoor Air Temperature
95
°
F DB
Full Load Conditions : Indoor Air Temperature
80
°
F DB / 67
°
F WB
Outdoor Air Temperature 115
°
F DB
Heating:
Rating Conditions
: Indoor Air Temperature
70
°
F DB / 60
°
F WB
Outdoor Air Temperature
47
°
F DB / 43
°
F WB
Full Load Conditions : Indoor Air Temperature
80
°
F DB / —
°
F WB
Outdoor Air Temperature
45
°
F DB / 35
°
F WB
Indoor model: UH2442 / Outdoor model: CH2442
●
Cooling
●
Heating
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230 - 208 V / 1 phase / 60 Hz
230 - 208 V / 1 phase / 60 Hz
Rating conditions
A
0.9 - 0.8
0.9 - 0.9
9.7 - 10.4
11.5 - 12.1
kW
0.18 - 0.16
0.18 - 0.17
2.19 - 2.15
2.55 - 2.48
Full load conditions
A
0.9 - 0.8
0.9 - 0.9
11.1 - 12
12.9 - 13.7
kW
0.18 - 0.16
0.18 - 0.17
2.53 - 2.48
2.89 - 2.81
Starting amperes
A
2 - 2
1 - 1
66 - 60
67.9 - 61.8
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230 - 208 V / 1 phase / 60 Hz
230 - 208 V / 1 phase / 60 Hz
Rating conditions
A
0.7 - 0.7
0.9 - 0.9
10.4 - 10.9
12 - 12.5
kW
0.16 - 0.14
0.18 - 0.17
2.31 - 2.24
2.65 - 2.55
Full load conditions
A
0.7 - 0.7
0.9 - 0.9
11.2 - 12.2
12.8 - 13.8
kW
0.16 - 0.14
0.18 - 0.17
2.49 - 2.47
2.83 - 2.8
Starting amperes
A
2 - 2
1 - 1
66 - 60
67.7 - 61.7