I - 108
SM830082
1
2
3
4
5
1. Specifications
Cooling:
Rating Conditions
: Indoor Air Temperature
80
°
F DB / 67
°
F WB
Outdoor Air Temperature
95
°
F DB
Full Load Conditions : Indoor Air Temperature
80
°
F DB / 67
°
F WB
Outdoor Air Temperature 115
°
F DB
Heating:
Rating Conditions
: Indoor Air Temperature
70
°
F DB / 60
°
F WB
Outdoor Air Temperature
47
°
F DB / 43
°
F WB
Full Load Conditions : Indoor Air Temperature
80
°
F DB / —
°
F WB
Outdoor Air Temperature
45
°
F DB / 35
°
F WB
Indoor model: XH3642 / Outdoor model: CH3642
●
Cooling
●
Heating
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230 - 208 V / 1 phase / 60 Hz
230 - 208 V / 1 phase / 60 Hz
Rating conditions
A
0.9 - 0.8
1.8 - 1.8
12.7 - 13.2
15.4 - 15.8
kW
0.20 - 0.16
0.36 - 0.34
2.79 - 2.70
3.35 - 3.20
Full load conditions
A
0.9 - 0.8
1.8 - 1.8
15.4 - 16.7
18.1 - 19.3
kW
0.20 - 0.16
0.36 - 0.34
3.43 - 3.41
3.99 - 3.91
Starting amperes
A
1 - 1
2 - 2
95 - 86
98 - 89
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230 - 208 V / 1 phase / 60 Hz
230 - 208 V / 1 phase / 60 Hz
Rating conditions
A
0.7 - 0.6
1.8 - 1.8
15.7 - 16.9
18.2 - 19.3
kW
0.16 - 0.12
0.36 - 0.34
3.33 - 3.29
3.85 - 3.75
Full load conditions
A
0.7 - 0.6
1.8 - 1.8
14.2 - 15.6
16.7 - 18.0
kW
0.16 - 0.12
0.36 - 0.34
3.16 - 3.21
3.68 - 3.67
Starting amperes
A
1 - 1
2 - 2
95 - 86
98 - 89