I - 61
SM830082
1
2
3
4
5
1. Specifications
Indoor Unit: TH4242
Outdoor Unit: CH4242
• 230V / 1 phase / 60Hz
RATING CAPACITY :
42,000 BTU/h
AIR FLOW RATE:
900 CFM
EVAPORATOR
CONDENSER
ENT.TEMP.
°
F(
°
C)
AMBIENT TEMP
°
F(
°
C)
WB
DB
75
85
95
105
115
(23.9)
(29.4)
(35.0)
(40.6)
(46.1)
TC
42,550
40,490
38,140
35,490
32,550
CI
3.03
3.3
3.6
4.02
4.44
72(22.2)
SHC
29,360
28,200
26,920
25,510
24,000
59
76(24.4)
SHC
32,530
31,380
30,090
28,690
27,170
(15.0)
80(26.7)
SHC
35,850
34,690
33,410
32,000
30,490
84(28.9)
SHC
39,020
37,860
36,580
35,170
32,550
88(31.1)
SHC
42,190
40,490
38,140
35,490
32,550
TC
44,140
42,170
40,070
37,670
35,070
CI
3.06
3.35
3.65
4.08
4.5
72(22.2)
SHC
25,230
24,220
23,160
21,990
20,740
63
76(24.4)
SHC
28,400
27,390
26,340
25,160
23,920
(17.2)
80(26.7)
SHC
31,720
30,710
29,650
28,470
27,230
84(28.9)
SHC
34,890
33,880
32,820
31,650
30,400
88(31.1)
SHC
38,060
37,050
36,000
34,820
33,580
TC
45,820
44,020
# 42,000
39,770
37,340
CI
3.08
3.38
3.69
4.12
4.55
72(22.2)
SHC
21,080
20,240
19,310
18,300
17,230
67
76(24.4)
SHC
24,260
23,410
22,480
21,470
20,410
(19.4)
80(26.7)
SHC
27,570
26,730
25,790
24,790
23,720
84(28.9)
SHC
30,740
29,900
28,970
27,960
26,890
88(31.1)
SHC
33,920
33,070
32,140
31,130
30,070
TC
48,260
46,580
44,770
42,800
40,610
CI
3.11
3.41
3.75
4.18
4.62
72(22.2)
SHC
17,020
16,300
15,540
14,720
13,840
71
76(24.4)
SHC
20,190
19,470
18,710
17,890
17,010
(21.7)
80(26.7)
SHC
23,510
22,790
22,020
21,210
20,320
84(28.9)
SHC
26,680
25,960
25,200
24,380
23,500
88(31.1)
SHC
29,850
29,130
28,370
27,550
26,670
TC
49,220
47,630
45,950
44,020
41,960
CI
3.17
3.47
3.8
4.24
4.69
75
76(24.4)
SHC
15,640
15,030
14,400
13,680
12,930
(23.9)
80(26.7)
SHC
18,960
18,350
17,710
16,990
16,240
84(28.9)
SHC
22,130
21,520
20,880
20,170
19,410
88(31.1)
SHC
25,300
24,690
24,060
23,340
22,590
TC :Total Cooling Capacity (BTU/h)
SHC:Sensible Heat Capacity (BTU/h)
CI :Compressor Input (kW)
Rating conditions are
M.R.=
14.78
USpints/h
:Outdoor Ambient Temp.95
°
FDB
:Indoor Unit Entering Air Temp.80
°
FDB/67
°
FWB