Brushless-inverter standard specification 

Applied motor 

Brushless motor 50W 

Power 

source 

Voltage 

Single-phase AC100-120V 

Single-phase/three-phase AC200-240V 

Permissible 

voltage range 

±

10

 

Frequency 

50

60Hz 

Variable-speed range 

General change gear ratio 1:76 

(Maximum change gear ratio 1:100) 

Environmental 

conditions 

Ambient 

temperature 

-10℃ to  +40℃

 

(Avoid freezing.) 

Ambient 

humidity 

Relative humidity 85% max. 

(Avoid condensation.) 

Atmosphere 

Indoor (Avoid splash of liquids, 

corrosive/flammable gases, dust, etc.) 

Elevation 

1000m or less 

NOTE: 1. Be sure to confirm that the power source voltage is within the rated voltage range, before 

turning ON the power source. 

2. Be sure to start and stop the conveyor with RUN/STOP switch. When starting and stopping the   

machine by external signals, use control circuit terminals on rear of inverter. (→See “Starting 

 

and Stopping the Conveyor by External Signals”, p.

12.) 

3. When leaving the conveyor unused for a long period, make sure that the power supply is off.   

(The RUN/STOP switch is not for turning the power on and off.) 

4. Before turning off the power supply, be sure to set RUN/STOP switch to “STOP” position, 

 

otherwise there is a risk that the motor will restart rotating unexpectedly when powered.   

Moreover make sure that RUN/STOP switch is in “STOP” position before turning on the 

 

power supply. 

  Variable-speed Range of Brushless-inverter 

(Torque at high speed can be used at low speed as well.) 
 
Nominal speed (motor rotation: 2300 r/min) is determined as the lower limit of RED ZONE. Variable-
speed range up to the lower limit of RED ZONE is 1:76 (motor rotation: 30-2300 r/min). 
By using RED ZONE up to the upper limit, it is possible to vary speed up to 1.3 times of nominal speed 
(variable-speed range: 1:100, motor rotation: 30-3000r/min). 
NOTE: Since motor rotation increases as the speed gets closer to the upper limit of RED ZONE, this will   

increase noise and shorten service life of gear head. Use the machine at appropriate speed to 
avoid these troubles. 

 Brushless-inverter operating panel

Speed control

Alarm LED (red)

Power LED (green)

Rotation-direction
selecting switch
(CW/CCW)

RED ZONE
(necessary to use
carefully)

This border is standard.

(If accurate speed required,
actually measure speed
or use setting device B.)

RUN/STOP switch

Содержание MAGDRIVE CLAM

Страница 1: ...1 OPERATING AND SERVICE MANUAL Sanki Non contact Magnetic Drive Conveyor MAGDRIVE CLAM CLDM and CLAMC models...

Страница 2: ...at it may be referred to when needed For the following models refer to the separate operating and service manual Sanki Clean Conveyor Applied models CLAA CLAD and CLAC models TABLE OF CONTENTS 1 Cauti...

Страница 3: ...odel code Power source frequency and belt speed in m min eg 50Hz 15 7m min Nominal roller width in cm eg 50cm Roller pitch in cm 2 digits eg 2cm Power source eg 200V three phase Motor type and Motor o...

Страница 4: ...touch electrical parts with wet hands Do NOT use in an explosive atmosphere Avoid explosive gas explosive dust etc Lower cover and guard Install the optional lower cover or guard in order to prevent e...

Страница 5: ...the sides of the conveyor Injury may result from a toppling conveyor Toppling prevention When using the conveyor be sure to secure it to the floor ground with anchor bolts etc to prevent it from toppl...

Страница 6: ...6 2 COMPONENT NAMES 2 1 ACCUMULATING TYPE CLAM MODEL AND LIVE ROLLER TYPE CLDM MODEL...

Страница 7: ...7 2 2 CORNER ROLLER TYPE CLAMC MODEL...

Страница 8: ...ING STANDS 3 ASSEMBLY NOTE When changing installation positions of stands pay special attention to balance of conveyor for safety 3 2 INSTALLING GUIDE RAILS OPTIONAL Installing guide rails optional eg...

Страница 9: ...Control devices switch etc are optional 3 3 CONTROL UNIT INSTALLATION BE SURE TO SWITCH OFF POWER SUPPLY Before starting procedures below be sure to stop conveyor and switch off power supply In addit...

Страница 10: ...on indicator is illuminated in green 2 Set RUN STOP switch to RUN position Motor will start rotating and conveyor will run 3 To increase speed turn speed control clockwise to decrease speed turn it c...

Страница 11: ...g the power on and off 4 Before turning off the power supply be sure to set RUN STOP switch to STOP position otherwise there is a risk that the motor will restart rotating unexpectedly when powered Mo...

Страница 12: ...with I O connector Item number DV0PM20076 sold separately N FB L 3 L 2 L 1 Noise filter NOTE For single phase power source connect power source input terminals to L1 and L2 Caution When Using brushles...

Страница 13: ...ilt in protective function against overload overcurrent overheat etc In emergency brushless inverter trips and alarm LED is illuminated in red NOTE 1 When brushless inverter trips immediately set RUN...

Страница 14: ...UN position belt running will be rapidly reversed and the inverter may trip due to inertia of load In this case alarm LED will be illuminated in red 2 Machine without Reverse Switch To change directio...

Страница 15: ...15 MEMO...

Страница 16: ...by loosening attachment bolts with a hexagonal wrench 3 Hold both ends of broken defective carrying roller 3 and raise the entire carrying roller vertically Bearings 4 of both roller ends will then be...

Страница 17: ...om center frame bearing holder 4 4 Attach center frame bearing holder 4 to replacement carrying roller 5 5 Referring to fig B simultaneously insert both ends of replacement carrying roller 5 into slot...

Страница 18: ...lts 4 Disconnect cable coming out of geared motor from control unit 5 Tightly fix replacement geared motor 4 to motor bracket 5 with attachment bolts 3 4 bolts 6 Reinstall drive gear 6 or timing pulle...

Страница 19: ...t geared motor 6 Attach geared motor 3 to corner base 5 by tightening attachment bolts 2 4 bolts Make sure that crossed helical gear of geared motor and line shaft side crossed helical gear are proper...

Страница 20: ...o touch other magnets 4 Fit center of replacement magnet 5 to center of O ring 6 on carrying roller shaft If O ring 6 is broken defective replace it also 5 Reinstall collar 7 and bearing 4 in initial...

Страница 21: ...the O ring 6 of removed broken defective magnet on line shaft 10 NOTE Fit center of magnet 9 to center of O ring 6 If O ring is broken defective replace it as well 5 To restore line shaft correctly re...

Страница 22: ...lt 5 loosen attachment bolts 3 4 bolts and move geared motor 4 slightly downward 3 Properly adjust timing belt tension Fix geared motor 4 by tightening attachment bolts 3 4 bolts 4 Reinstall drive uni...

Страница 23: ...shaft 14 together with timing belt from geared motor bracket 10 Then remove timing belt 5 from driving line shaft 14 5 Install replacement timing belt to driving line shaft 14 Correctly position timin...

Страница 24: ...spection and correction repair or replacement Inspect remove foreign substance and clean Inspect and reduce load Inspection and repair or replacement Inspection and repair or replacement Take up belt...

Страница 25: ...ion malfunction of magnet parts and bearing parts Visual inspection and manual check Inspection and adjustment repair or replacement See p 21 Drive unit Trouble of driving transmission parts Visual in...

Страница 26: ...26 MEMO...

Страница 27: ...27 MEMO...

Страница 28: ...23 01 hansou jp Contact us Particular attention is given to the manufacture and transportation of SANKI conveyors However if you need any information about the use or failure of the machine or any oth...

Отзывы: