Brushless-inverter standard specification
Applied motor
Brushless motor 50W
Power
source
Voltage
Single-phase AC100-120V
Single-phase/three-phase AC200-240V
Permissible
voltage range
±
10
%
Frequency
50
/
60Hz
Variable-speed range
General change gear ratio 1:76
(Maximum change gear ratio 1:100)
Environmental
conditions
Ambient
temperature
-10℃ to +40℃
(Avoid freezing.)
Ambient
humidity
Relative humidity 85% max.
(Avoid condensation.)
Atmosphere
Indoor (Avoid splash of liquids,
corrosive/flammable gases, dust, etc.)
Elevation
1000m or less
NOTE: 1. Be sure to confirm that the power source voltage is within the rated voltage range, before
turning ON the power source.
2. Be sure to start and stop the conveyor with RUN/STOP switch. When starting and stopping the
machine by external signals, use control circuit terminals on rear of inverter. (→See “Starting
and Stopping the Conveyor by External Signals”, p.
12.)
3. When leaving the conveyor unused for a long period, make sure that the power supply is off.
(The RUN/STOP switch is not for turning the power on and off.)
4. Before turning off the power supply, be sure to set RUN/STOP switch to “STOP” position,
otherwise there is a risk that the motor will restart rotating unexpectedly when powered.
Moreover make sure that RUN/STOP switch is in “STOP” position before turning on the
power supply.
■
Variable-speed Range of Brushless-inverter
(Torque at high speed can be used at low speed as well.)
Nominal speed (motor rotation: 2300 r/min) is determined as the lower limit of RED ZONE. Variable-
speed range up to the lower limit of RED ZONE is 1:76 (motor rotation: 30-2300 r/min).
By using RED ZONE up to the upper limit, it is possible to vary speed up to 1.3 times of nominal speed
(variable-speed range: 1:100, motor rotation: 30-3000r/min).
NOTE: Since motor rotation increases as the speed gets closer to the upper limit of RED ZONE, this will
increase noise and shorten service life of gear head. Use the machine at appropriate speed to
avoid these troubles.
●
Brushless-inverter operating panel
Speed control
Alarm LED (red)
Power LED (green)
Rotation-direction
selecting switch
(CW/CCW)
RED ZONE
(necessary to use
carefully)
This border is standard.
(If accurate speed required,
actually measure speed
or use setting device B.)