Circuit Protector
(1) Constant-speed Type
To prevent motor from burning out due to overload etc., it is recommended to provide the
machine with a circuit protector(optional). When protector is activated and conveyor stops,
reset button pops out. In this case always switch off power and set RUN/STOP switch to
“STOP”. Reset button may be pressed in to restore circuit, and machine can be restarted by
setting RUN/STOP switch to “RUN”.
NOTE: Before restarting machine, carefully check for cause of stoppage and ensure it is
removed.
(2) Brushless-inverter Variable speed Type
Brushless-inverter has built-in protective function against overload, overcurrent, overheat, etc.
In emergency, brushless-inverter trips and alarm LED is illuminated in red.
NOTE: 1. When brushless-
inverter trips, immediately set RUN/STOP switch to “STOP”
position and turn off power supply. Before restarting machine, carefully check for
cause of trip and ensure it is removed.
2. When voltage is insufficient, alarm LED is illuminated in red. However, brushless
inverter does not trip in standard circuit.
3. For increased safety, separately install overcurrent protective device on power source
side.
Reverse switch
(optional)
Circuit protector reset button
(optional)
●
Constant-speed Type
●
Brushless-inverter Variable speed Type
Speed control
Alarm LED (red)
Power LED (green)
Rotation-direction
selecting switch
(CW/CCW)
RUN/STOP switch
Содержание MAGDRIVE CLAM
Страница 6: ...6 2 COMPONENT NAMES 2 1 ACCUMULATING TYPE CLAM MODEL AND LIVE ROLLER TYPE CLDM MODEL...
Страница 7: ...7 2 2 CORNER ROLLER TYPE CLAMC MODEL...
Страница 15: ...15 MEMO...
Страница 26: ...26 MEMO...
Страница 27: ...27 MEMO...