10.9 Configuration Management
The APC supports the following functions for configuration management.
Saves the current configuration information.
Exports/imports the current configuration information (import/export).
Initializes system
Configuration using CLI
[Save Configuration information]
To save the current configuration information in the system, execute the command as
follows:
WEC8500# save local
[Export Configuration information]
To transmit the current configuration information in the system to outside, execute the
command as follows: When you execute the command, the configuration information is
compressed into the entered ‘FILENAME’ as a file.
WEC8500# export [FILENAME]
[Import Configuration information]
In addition, to apply a file (‘FILENAME’) from outside to the current system, execute the
command as follows:
WEC8500# import [FILENAME]
[Periodic backup configuration information]
Excute following command to transfer configuration information to ftp/sfpt server.
filename: System MAC_Package Version_backup time.wec8500.config [wec8050.config]
1) Enter to CLI periodic-backup mode.
WEC8500# configure terminal
WEC8500/configure# periodic-backup
WEC8500/configure/periodic-backup#