Ver.
Smart MBS RRH-P4 Installation Manual/Ver.3.0
© SAMSUNG Electronics Co., Ltd.
2-39
2600-00CTEIGAA
4.0
Caution for installing the power cable
To maintain cable gland’s rain protection performance, 11.81 in. (300 mm) or
more interval should be kept straight. According to the radius of curvature of the
cable specification should be considered.
Caution for cutting the power cable
Cut power cable after installing power cable to RRH-P4 power terminal taking into
account the radius of curvature according to the cable specifications.
When cutting the cable first, the length difference of cable end can be occurred by
cable curvature and the power terminal may cause contact fault.
6) Remove the power terminal protection cap from the power terminal block.
Figure 2.29 Connecting RRH-P4 power cable (AWG8) (3)
Stainless steel Band
or Cable Tie
≒
11.81 in. (300 mm) or more
≒
11.81 in. (300 mm)
≒
11.81 in. (300 mm)
RTN
-48 V
Power Terminal Protection Cap
Power Terminal block