2.8.5 Hybrid Cable Shield Grounding Connection
Follow the steps below to connect the shield ground cable of hybrid cable to the ground bar
in the DU cabinet.
Figure 2.43 Hybrid Cable Shield Grounding Connection_DU Cabinet
1) Install the shield ground cable of hybrid cable to the ground bar on the left of the DU cabinet.
2) Remove the M6 Hex. nuts and lock washers installed in the ground bar.
3) Align the pressure terminal assembled on the cable to the insert bolt of the ground bar, and fasten it
using the removed M6 Hex. nut and lock washer.
Shield Ground Cable of Hybrid Cable
M6 Lock Washer
M6 Hex. Nut
Shield Ground Cable of Hybrid Cable #2
Shield Ground Cable of Hybrid Cable #1
Shield Ground Cable of Hybrid Cable #0
Ground Bar (in DU Cabinet)
Pressure Terminal