RRH-P4 optic cable connection standard
Cable connection standard between UADU CPRI port and RRH-P4 optic port is
different according to the count (One or two) of CDMA UADU (Installed in DU
cabinet).
Connect the optic cable (Refer to the connection standard of ‘table 2.6’ and ‘table
2.7’). Because false connection can cause the fault of call connection, be cautious.
Caution when Installing the RF antenna
To protect from lightning, the RF antenna must be installed within the shielding
angle as shown below, considering the downward distance and the angle from
the tower lightning rod or the antenna pole lightning rod.
- The protection angle of the lightning rod should be 45 degrees.
Finishing Heat Shrink Tube of a Sector Antenna
1) Insert an antenna protection plate.
2) Place the heat shrink tube on the connection point and shrink the heat shrink
tube using a heat gun.
3) Avoid aiming the heating gun toward the antenna’s body.