OfficeServ 7100
PROGRAMMING
TECHNICAL MANUAL
PART 2 MAY 2009
MMC: 820
ASSIGN SYSTEM LINK ID
DESCRIPTION:
This MMC is used to assign the system link ID for QSIG and IP networking. In the
case of IP networking this MMC is also used to set the IP address and other settings
related to the various network links, or “nodes”.
OPTION DESCRIPTION
LINK ID
This is the unique system identifier associated with a network
node.
SIGNAL G/W
This field is the IP address used to connect to the network node.
TIME SYNC
This option allows the OfficeServ 7100 to sync the internal clock to
an IP network node.
IP TYPE
This field determines if an IP network node is
PUBLIC
or
PRIVATE
in relation to the OfficeServ 7100.
PRIVATE
references a device
that is on the same subnet,
PUBLIC
references a device on a
different subnet.
NODE NAME
This field sets a name to associate with a network node. This field
is mainly for technician reference and is not used elsewhere in the
system.
NO MGI
This option determines is communications with this IP network
node should use MPS channels or MGI channels. The default
setting of
OFF
means that only MGI channels will be used.
ON
means that MPS channels will be used.
NOTE:
This option is only displayed if the
MPS SERVICE
is
ENABLED
in MMC 861.
CODEC
This field determines the audio codec to use when communicating
with an IP network node. The default setting is
G729a
. Available
alternatives are
G711u-law
and
G711a-law
.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SPEAKER
Used to store data and advance to next MMC
HOLD
Used to delete an entry
Home Page