OfficeServ 7100
PROGRAMMING
TECHNICAL MANUAL
PART 2 AUGUST 2007
MMC: 112
ALARM CLOCK
DESCRIPTION:
Allows the system administrator or technician to set or change the alarm
clock/appointment reminder feature for any analog station. This must be done for
single line telephones, as they cannot access programming. Three alarms may be
set for each station and each alarm may be defined as a one-time or TODAY alarm
or as a DAILY alarm, as described below. The TODAY alarm is automatically
cancelled after it rings, while the DAILY alarm rings every day at the same time.
Alarm numbers are 1, 2 and 3. In the case of Secondary Pair assignments (MMC
217) the alarm only rings the station that is programmed and does not ring the
paired station.
Entry
Alarm Type
Dial 0
NOTSET
Dial 1
TODAY
Dial 2
DAILY
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
SPEAKER
Used to store data and advance to next MMC
HOLD
Used to clear previous entry
ACTION DISPLAY
1. Press TRANSFER 112
Display shows
[201] ALM CLK(1)
HHMM:
Î
NOTSET
2. Dial station number (e.g., 205)
OR
[205] ALM CLK(1)
HHMM:
Î
NOTSET
Press UP or DOWN to select station and press
RIGHT soft key.
3. Dial 1~3 to select alarm (e.g., 1)
OR
[205] ALM CLK(1)
HHMM:
Î
NOTSET
Press UP or DOWN to select alarm and press
RIGHT soft key.
Home Page
Table of Contents