OfficeServ 7100
PROGRAMMING
TECHNICAL MANUAL
PART 2 APRIL 2007
MMC: 804
STOP BIT
Dial 1
1 bit
Dial 2
2 bit
WAIT: 0030 sec (0000-99900)
DSR CHECK: OFF
Dial 0: OFF
Dial 1: ON
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
SPEAKER
Used to store data and advance to next MMC
HOLD
Used to clear entry (when valid)
ACTION
DISPLAY
1. Press TRANSFER 804.
Display shows.
SYS I/O PORT :1
SERVICE:NOT USE
2. Enter parameter desired via dial keypad
(e.g., 1) from the above option list
SYS I/O PORT :1
SERVICE:PCMMC
OR
Press UP or DOWN key to make selection.
Press RIGHT soft key to move cursor.
3. Press TRANSFER to store and exit
OR
Press SPEAKER to store and advance to
next MMC.
DEFAULT DATA: SERVICE
PORT 1
NOT USE
BAUD RATE
19200 BPS
CHAR LENGTH 8 BITS
PARITY
NONE
RETRY
COUNT
03
STOP BIT
1 BIT
WAIT TIME
0030 MSEC
DSR
CHK
OFF
RELATED ITEMS: