OfficeServ 7100
PROGRAMMING
TECHNICAL MANUAL
PART 8 APRIL 2007
8.1.6
Register
Description
ORBIT
This register is no longer used by the system and can be used as a free
variable for applications.
DATE
This register is read only and stores the current system date.
ACCNT
The Account register stores the Long Distance Account code entered in the
Account Code field of the Extension block most recently accessed. This
register is blank if the caller has not been connected to an Extension block, or
if the Extension block's Account Code field is blank.
LANG
This register is used to define the system language currently in use. This
register may only store a single digit value, and that value must be defined on
the Language screen of the System Parameters menu.
REG1
This register is blank by default and can be used freely for storing data for
applications.
REG2
This register is blank by default and can be used freely for storing data for
applications.
REG3
This register is blank by default and can be used freely for storing data for
applications.
REG4
This register is blank by default and can be used freely for storing data for
applications.
NAME
This register is only used with Speak blocks and will speak the name most
recently recorded by the Call Screening feature.
EXT
This register is only used with Speak blocks and will speak the Extension
number last accessed.
MBX
This register is only used with Speak blocks and will speak the Mailbox number
last accessed.
X
This register is read only and is used when dialing out of a Mailbox block for
message notification. It stores the Extension number that is associated with this
Mailbox. If there is no associated Mailbox block this value is blank.
B
This register is read only and is used when dialing out of a Mailbox block for
message notification. It stores the callback phone number entered by the caller
for the most recent message. If no callback number was entered this value is
blank.
N
This register is read only and is used when dialing out of a Mailbox block for
message notification. It stores the number of new messages in the Mailbox
block.
S
This register is read only and is used when dialing out of a Mailbox block for
message notification. It stores the number of saved messages in the Mailbox
block.
8.1.6 Special Dialing Characters
Certain block types will allow the technician to enter a dialing string. The following chart
explains the special characters available for entry into these dial strings.
Character(s) Function
&
The ampersand tells the system to perform a flash-hook
,
The comma inserts a one second pause
\
The backslash inserts a four second pause
T
Capital T tells the system to use DTMF dialing
W
Capital W tells the system to wait for an answer
;
The semicolon tells the system to wait for dial tone
Home Page
Table of Contents