42 _ Troubleshooting
Item
Related
Parts
Symptoms
Description
Manual Mode
Configuration
※
When performing this STEP without performing STEP 1 as it has been already performed, calibrate the pressure in the tub when
restarting or operating the nozzle for the first time.
※
If STEP 1 has not been performed before, perform STEP 1 first.
(STEP 1 is not recognized as having been performed if STEP 1 is re-operated, STEP 6 has been performed or Auto Mode has been
enabled.)
※
For models with vane, the vane must move back and forth when the bottom alternation is in progress.
3. [Manual Mode STEP 3: inspect the heater]
- Set the alternation to the default position.
- Circulation pump: operate BDLC Model at 2400RPM, and AC model at LOW Power setting.
- Operate the heater after operating the circulation pump for 10 seconds.
- Turn the heater off when the max. temperature reaches 73 degrees or the max. operation time passes 10 minutes.
- During operation, the display alternates between the temperature of the heater and the current Step No.
※
When performing this STEP without performing STEP 1 as it has been already performed, calibrate the pressure in the tub when
restarting or operating the nozzle for the first time.
※
If STEP 1 has not been performed before, perform STEP 1 first.
Only "3" blinks during STEP 1 operation (no display of temperature).
(STEP 1 is not recognized as having been performed if STEP 1 is re-operated, STEP 6 has been performed or Auto Mode has been
enabled.)
4. [Manual Mode STEP 4: operate the dispenser]
- Operate the dispenser for 130 seconds.
5. [Manual Mode STEP 5: operate the fan]
1) Operate the Fan Motor and Dry Actuator for 30 seconds. (Only for models with the relevant part)
6. [Manual Mode STEP 6: drain]
1) Operate the drain pump.
2) Follow the same steps as PreDrain.
3) If water level is not detected after draining, the drain inspection code is activated.
4) For models without low water level detection, proceed to the next step after draining without the drain inspection code.
7. [Manual Mode STEP 7: operate Auto Door Open Actuator]
1) Operate Auto Door Open Actuator.
- If the Door does not open within 3 minutes after the Auto Door Open Actuator is run, it will Retry once
(10 seconds Off, 3 minutes On).
- If the Door does not open after the retry, a DC3 check code will occur.
Before the DC3 check code occurs, operate the Auto Door Open Actuator for an additional 30 seconds during Door open detection.
Information Display
Each time Hi-Temp Wash Key is pressed while "AS“ displays, it makes [SOUND_KEYPUSH] sound and changes in the
following order: n1 → n2 → n3 → n4 → n5 → n1 → n2 → n3...changes in a loop
- When Auto Key is pressed while the information display mode is on, it makes [SOUND_KEYPUSH] sound and returns to Auto Mode.