18 _ Disassembly and Reassembly
Part
Figure
Description
Assy Case Brake
4. Separate connection parts in red circle from tub and
pull out the Case brake by lifting up the hook in red
square.
1. Drain hose
2. Drain pump out
3. Assy guide
water-sub
4. Loosen the three (3) clamps and release the three
(3) hoses from the Assy case brake.
Caution
Water remaining in the Assy case sensor and Assy
case break will come out. Lay a towel on the floor to
absorb any water that may come out.
When reassembling, the holder of the clamp must be
pointing toward the inside of the dishwasher.
Assy guide water-
sub
Clamp
Preparation:
• Disassemble the Assy Case Brake.
- Refer to the “Assy Case Brake” disassembly
section to separate Assy case brake until step 4.
1. Separate the Assy guide water-sub from base by
bending two fixed hook.
2. Separate the Assy guide water-sub from connected
hose by disassembling the clamp.