8 | SAMLEX AMERICA INC.
SECTION 3 |
Installation
3.2 DIMENSIONAL DRAWING
Dimensional drawing is given at Fig 3.1 below:
126
+
–
+
–
+
–
Height: 37
NOTE
: All dimensions are in mm
69.3
6
138.6
Mounting Hole: 4.3 mm
Terminals: 4 mm
2
4.3
34.65
Fig 3.1: Dimensional Drawing of Charge Controller MSK-10A
3.3 MOUNTING
Refer to Fig 3.2
When mounting the controller, ensure free air through the ventilation slots at the bottom of the
unit. There should be at least 6 inches (150 mm) of clearance above and below the controller to
allow for cooling. If mounted in an enclosure, forced air ventilation is highly recommended.
WARNING!
RISK OF EXPLOSION! NEVER INSTALL THE CONTROLLER IN A SEALED ENCLO-
SURE WITH FLOODED BATTERIES! DO NOT INSTALL IN A CONFINED AREA
WHERE BATTERY GASSES CAN ACCUMULATE.
MISE EN GARDE!
RISQUE D'EXPLOSION! N'INSTALLEZ JAMAIS LE CONTRÔLEUR DANS UN
BOÎTIER SCELLÉ AVEC DES BATTERIES INONDÉES! NE PAS INSTALLER DANS
UNE ZONE CONFINÉE OÙ DES GAZ DE BATTERIE PEUVENT S'ACCUMULER.