16 | SAMLEX AMERICA INC.
SECTION 4 |
Operation
4.4.1.3.1 Automatic Exit from Float Stage to Absorption Stage
The charger will exit Float Stage and enter Absorption Stage (Section 4.4.1.2) automatically as
follows:
(i) During Float Stage, if the load current is more than the current supplied by the Solar Panel(s),
the battery voltage will drop. The battery voltage will also drop due to self discharge if there is
no sun for prolonged period of time or, if the Solar Pannel / Solar Array gets disconnected. If
the battery voltage drops to 13.2V for 12V battery or 26.4V for 24V battery, the Controller will
revert to Stage 2 - Absorption Stage (
Section 4.4.1.2
) or,
(ii) If the Controller has remained in Float Stage for 28 days
4.4.2 Equalization Charging Profile
4.4.2.1 Equalization of Lead Acid Batteries - General Information
WARNING!
RISK OF EXPLOSION AND EQUIPMENT DAMAGE!
• Equalizing Flooded Battery can produce explosive gases. Ensure proper ventilation of
the battery box housing of the Flooded Battery
• Equalization may increase battery voltage to the level that can damage sensitive DC
loads. Ensure that DC input voltage of all DC loads is greater than the Equalizing
Charging Set Point. DC loads not matching Equalization Voltage Set Point,
Ve (Fig 4.1B) should be disconnected.
!
CAUTION!
• Top up the electrolyte with distilled water after completion of equalization of
Flooded Battery.
• Excessive overcharging and gassing too vigorously can damage the battery plates
and cause shedding of active material from the plates. An equalization that is too
high or for too long can be damaging.
Review the requirements for the particular
battery being used in your system
.
MISE EN GARDE!
RISQUE D'EXPLOSION ET DE DOMMAGES MATÉRIELS!
• L'égalisation de la batterie inondée peut produire des gaz explosifs. Assurer
une ventilation adéquate du boîtier du boîtier de batterie de la batterie inondée
• L'égalisation peut augmenter la tension de la batterie au niveau qui peut
endommager les charges CC sensibles. Assurez-vous que la tension d'entrée
CC de toutes les charges CC est supérieure au point de consigne de charge
d'égalisation. Les charges CC ne correspondant pas au point de consigne de
tension d'égalisation doivent être déconnectées.