20 | SAMLEX AMERICA INC.
SECTION 4 |
Operation
TABLE 4.1 LED INDICATIONS FOR OPERATIONAL STATUS (Continued)
Location
of LED
(Fig 2.1)
Function of LED
Color
of LED
LED Lighting
Pattern
Operational Status
1,2,3
All 3 LED Indicators are blinking:
• Solar Panel / Array Status LED (
1, Fig 2.1
) = Blinks Green
• Battery Status LED (
2, Fig 2.1
) = Blinks Red
• Load Status LED (
3, Fig 2.1
) = Blinks Red
- Internal hot spot is >85
°
C
• Input and output are disconnected
Auto reset at <75
°
C
(See Section 5.1.12)
1,2,3
All 3 LED Indicators are blinking:
• Solar Panel / Array Status LED (
1, Fig 2.1
) = Blinks Green
• Battery Status LED (
2, Fig 2.1
) = Blinks Red
• Load Status LED (
3, Fig 2.1
) = Blinks Red
System voltage error. Battery voltage does
not match the controller voltage. Check
battery voltage is 12V/24V. Press Load
On/Off Button (4, Fig 2.1) to clear the
malfunction.
(See Section 5.1.14)
"System Voltage Error" due to:
1. Battery voltage is not within the range
of 8-32 VDC
4.6 LOAD ON/OFF CONTROL
When the controller is powered ON, press the Load On/Off Button (
4, Fig 2.1
) to toggle the load
ON and OFF. When load is ON, Load Status LED (
3, Fig 2.1
) will turn ON - RED.
Load On/Off Button (4, Fig 2.1) is also for clearing (i) "Load Overload" fault (
Section 5.1.4
),
(ii) "Load Short Circuit" fault (Section 5.1.5) and (iii) "System Voltage Error" (See Section 5.1.14)
4.7 BATTERY TEMPERATURE SENSING & COMPENSATION
Refer to Section 3.4.4 for details.