18 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 19
4.5 LED INDICATIONS
LED indications for operational status are shown at Table 4.1.
TABLE 4.1 LED INDICATIONS FOR OPERATIONAL STATUS
Location
of LED
(Fig 2.1)
Function of LED
Color
of LED
LED Lighting
Pattern
Operational Status
1
Solar Panel
Status LED
Green
On Steady
Low solar irradiance due to poor sunlight.
Solar Panel voltage is more than 8V but
less than the battery voltage and hence,
there is no charging.
Green
Slow Blinking (
1Hz
)
Solar Panel Voltage is > battery voltage.
Charging is taking place.
Green
Fast Flashing (
4Hz
)
Solar Panel, has been connected in reverse
polarity (
See Section 5.1.3
)
Green
OFF
(i) Solar Panel Voltage is < 5V due to:
• Night time or,
• Solar Panel is disconnected or,
(ii) Solar Panel Input Terminals (
5A, 5B in
Fig 2.1
)
2
Battery Status LED
Green
On Steady
Normal Battery Voltage is >12.4V / 24.8V
Green
Slow Blinking (
1Hz
)
Battery is fully charged
Green
Fast Blinking (
4Hz
)
Battery over voltage: 16V / 32V
• Auto reset at 15.0V / 30.0V
(
See Section 5.1.8
)
Orange
On Steady
Battery under voltage warning: 12V / 24V
• Auto reset at 12.2V / 24.4V
Red
On Steady
Battery is over discharged to 11.1 / 22.2V.
• Auto reset at 12.6V / 25.2V
(
See Section 5.1.10
)
Red
Slow Blinking (
1Hz
)
Battery over heated to >65°C. Charging
is stopped.
• Auto reset at <55°C
(See Section 5.1.11)
3
Load Status LED
Red
On Steady
Battery power to Load Terminals is ON
Red
Off
Battery power to Load Terminals is OFF
Red
Slow Flashing (
1Hz
)
Overload on the Load Terminals. Battery
power to Load Terminals is OFF
(
See Section 5.1.4
)
• Press Load On/Off (
4, Fig 2.1
)
Red
Fast Flashing (
4Hz
)
Short circuit at Load Terminals. Battery
power to Load Terminals is OFF
(See Section 5.15)
• Press Load On/Off (
4, Fig 2.1
)
SECTION 4 |
Operation
Table Continues on Next Page