Index revision : A
25
7118
10. Maintenance
10.1. Summary table of preventive maintenance
To be carried out when the maintenance indicator light on the GNM 6080 turns on.
WARNING : (*) Once either of these two time periods has elapsed.
Subassembly
Description
Part
Number
Qty
Minimum
replacement
period
Seat casing
O-ring - chemically inert
J3STKL046
1
3 months
O-ring - chemically inert
J3STKL075
1
3 months
Adapter
Flat seal
900014821
1
6 months
O-ring - FEP Viton
J2FENV288
1
12 months
Barrel
Seal cartridge
910015881
1
6 months or
500,000 handling
operations(*)
O-ring (Seal cartridge)
J3STKL005
1
3 months
O-ring - chemically inert
J3STKL014
1
6 months
O-ring - FEP Viton
J2FENV435
1
12 months
O-ring - chemically inert
J3STKL078
2
12 months
O-ring - chemically inert
J3STKL032
1
12 months
O-ring - chemically inert
J3STKL019
1
12 months
Handle
O-ring (electrical connector)
160000041
1
12 months
O-ring (handle base)
160000067
1
12 months
O-ring (air nipple)
J2FTCF018
1
12 months
J3STKL018
1
12 months
Air valve
O-ring - chemically inert (exterior
valve)
J3STKL005
1
12 months
O-ring - chemically inert (interior
valve)
J3STKL032
1
12 months
Seal ring
900010256
1
12 months
Nozzle
Sieve or flat seal depending on the
calibre
129609901
or
900012793
1
When
changing the
nozzle or every
month
Head ring
O-ring - FEP Viton
160000170
1
12 months