![SAMES KREMLIN Nanogun Airmix H2O Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/sames-kremlin/nanogun-airmix-h2o/nanogun-airmix-h2o_user-manual_3696968012.webp)
Index revision : A
12
7118
3.2. GNM 6080 control module
The
GNM 6080
control module serves to display the use parameters along with their settings.
Temperature default
: The temperature default forces the indicator lights (Rep. 11
and 12). Once the temperature drops below the minimum, the temperature indica-
tor light (Rep. 11) shuts off, and the operator has the option of deleting the default
by pressing the “Default Acknowledgement” button (Rep. 3).
Generator default
: This default combines all internal generator defaults. If it is impos-
sible to acknowledge this default, the problem would require a service call by the
repairs department, please contact
SAMES KREMLIN
.
1
Maintenance indicator light
2
High voltage default indicator light
3
Acknowledgement of defaults
4
Display of the voltage set point
5
Increase of the voltage set point
6
Bar graph of current consumption
7
Active, preset memory indicator lights
8
Selection of the active memory
9
Voltage bar graph
10
Decrease in the voltage set point
11
Temperature default indicator light
12
Generator default indicator light
13
Low-voltage cable default indicator light
Front side of the GNM 6080 control module
1
2
4
3
5
6
7
8
9
10
11
12
13