30
13
Service menu
Entering the menu requires entering
a service password.
Service settings
H1, H2, H3 settings
DHW circuit settings
System
Solar
Weather sensor
Temperature corrections
Manual control
Restore default settings
Touch screen calibration
H1 settings
Mode
Control method
➢
Constant value
➢
Weather control
Weather-set temperature
➢
Heat curve
➢
Curve parallel shift
Thermostat
Preset water temperature*
Reduce constant water temperature*
Reduce water temp. by thermostat*
Pump lock by thermostat *
Circuit name
H2, H3 settings
Mode
Control method
➢
Constant value
➢
Weather control
Water setpoint temperature*
Water temperature reduction value in
NIGHT mode*
Weather-control temperature
➢
Heat curve
➢
Curve parallel shift
Preset water temprature*
Reduce constant water temperature*
Thermostat
Reduce water temp. by thermostat *
Pump lock by thermostat *
Minimum temperature
Maximum temperature
Valve opening time
Operation in SUMMER
Mixer input dead zone
Proportional range
Integration time constant
Circuit name
Screed drying program*
Screed drying activation*
Ustawienia Obieg CWU
Mode
DHW minimum temperature
DHW maximum temperature
DHW priority
DHW operation extension
DHW pump circulation mode
DHW pump circulation standstill time
DHW pump circulation operation time
Circulation pump start temp.
DHW hysteresis
Legionella
Heat loss protection
System settings
Main heat source
➢
Mode
➢
Hysteresis
➢
Minimum temperature
➢
Maximum temperature
➢
Boiler cooling temperature
➢
Temperature of start pumps
➢
Increasing preset temperature
➢
Pump operation extension
➢
Start delay
➢
Off by no heat demand
➢
Control mode
Additional heat source
➢
Selection
➢
Temp. deactivation of main heat
source
➢
Temperature of start pumps
➢
Boiler cooling temperature
Hydraulic scheme
Frost protection mode
Frost protection mode - delay time
Frost Protection setpoint temperature
Time automatic blocking pumps
Messages
Reaction on vacation mode
➢
Night temp stabilization
➢
Frost protection mode
Solar settings*
Mode
Delta T pump activation
Delta T pump deactivation
Minimum collector temperature
Maximum collector temperature
Collector deactivation temperature
Minimal pump rotations
Frost protection mode - solar
DHW maximum temperature
Night cooling
Temperature corrections
Weather sensor