38
14
Fuse replacement
The mains fuse is located under the housing
cover. It protects the regulator and other
devices. In case of replacement, use fuse
6.3A, 5x20mm.
In order to take out the fuse, raise the fuse
holder using flat-blade screwdriver and take
out the fuse.
15
Technical data
Power
230V~, 50Hz
Current consumption by
the controller
0,2 A
Max. rated current
6 (6) A
IP rating of the controller IP20
Ambient temperature
0...50
C
Storage temperature
-15...65
C without
direct sunlight
Relative humidity
5 - 85% without
steam condensation
Temp. measurement
range of sensors CT-10
0…
100
C
Temp. measurement
range of sensors CT6-P
-40...+40
C
Accuracy of temp.
measurement using
sensors CT-10 and CT6-P
±2
C
Connectors
Screw terminals at
supply voltage side -
2.5mm
2
Screw terminals at
control voltage side -
1.5mm
2
Graphical display with
touch panel
Display 480x272 pix.
Dimensions
340x225x60mm
Weight
1,6kg
Norms
PN-EN 60730-2-9
PN-EN 60730-1
Software class
A, wg PN-EN 60730-1
Protection class
I class
Pollution degree
2nd pollution degree,
PN-EN 60730-1
Mounting
on the wall
Note:
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………
…………………………………………………………………………