Work mode setting
It is possible to select work mode which is
suitable for user’s requirements
. The
operating mode can be selected directly on
the main window, press the mode icon.
Work mode
OFF
The controller switch off a
particular heating circuit or
DHW tank. Anti
–
freeze
function
remains
active
provided that is in active in
service menu. Activating this
mode also disables the heat
source. The heat source is not
switched off when the heating
function of the buffer is active.
AUTO
Preset room temperature is
switched between “
DAY
” and
“
NIGHT
”
temperatures
depending on clock indications
and defined time programs for
particular days of the week.
DHW tank is loaded during a
period corresponding to “
DAY
”
temperature.
For
time
programs corresponding to
“
NIGHT
” t
emperature, the
DHW tank is off.
DAY
Comfort mode.
In the heating circuit the
preset temperature is constant
or depending on the weather
and corresponds the entered
“
DAY
”
value.
HUW
tank
maintains constant preset
temperature.
NIGHT
Economy mode.
In the heating circuit in
"NIGHT" mode, the preset
temperature is decrease by the
entered value.. It is not
possible to select this mode for
DHW tank.
Auto-Eco
Preset room temperature is
maintained within defined time
periods
as “DAY” temperature.
Circuit is off outside the
defined time periods. Anti
–
freeze function remains active
provided that is in active in
service menu. It is not possible
to select this mode for DHW
tank.
Work mode can be selected separately for
each heating circuit and separately for DHW
tank.
Auto-Eco
and
NIGHT
modes are not
available for HUW tank.
The operating modes are inactive
when the heating circuits are
controlled by thermostats with
ON-OFF contacts, because on the
thermostats
set
the
preset
temperatures, reduce of the
temperatures or time schedules.
Software update
Software can be modified with the use of
microSDHC memory card.
In order to change the program, insert the
memory card into a slot in the control panel.
New software should be saved in *.pfc format
on a memory card in a form of two files: file
with a program for the control panel and file
with a program for the controller A module.
Save new software directly on a memory card.
Do not nest data in a sub-folder.
Enter:
Basic settings
→
Software update
and exchange the program first in the
controller module and then in the control
panel.
Содержание Multi-Mix
Страница 7: ...7 USER SETTINGS Multi Mix ...
Страница 13: ...INSTALLATION AND SERVICE SETTINGS Multi Mix ...
Страница 39: ...39 ...
Страница 40: ...40 SALUS Controls ul Rolna 4 43 262 Kobielice www salus controls pl ...