26
Hydraulic scheme no. 8 -
diagram “B” with heat buffer with layered charging buffer
8
:
1
–
boiler
2
–
heat buffer
3
–
additional heat source (fireplace)
4
–
controller
5
–
boiler pump
6
–
HUW pump
8
–
H1 circuit pump
9
–
H2 circuit pump
10
–
valve electrical servo of adjustable circuit (H2)
11 - DHW circulating pump
12 - solar panel
13 - solar pump
H1-S
–
upper sensor temperature buffer
WS - weather sensor
DHW
–
DHW tank temperature sensor
SH - collector solar temperature sensor
SL - lower temperature sensor DHW tank (lower solar
sensor).
PROPOSED SETTINGS:
Parameter
Setting
MENU
Hydraulic diagram
8
menu
→
service setting
→
System
Pump start temperature
25
C
menu
→
service setting
→
System
Mode
ON
menu
→
service setting
→
System
→
Main heat source
Minimum temperature
40
C
menu
→
service setting
→
System
→
Main heat source
Selection
ON
menu
→
service setting
→
System
→
Main heat source
Temperature deactivating main
heat source
35
C
menu
→
service setting
→
System
→
Main heat source
Pump start temperature
55
C
menu
→
service setting
→
System
→
Additional heat source
DHW mode
ON
menu
→
service setting
→
HUW settings
8
Shown hydraulic diagram does not replace a central heating system and can be used only for demonstrative purposes
!