11
of the week. Due to this, entering time periods
is quick and intuitive.
Operation within tim
e periods for “DAY” and
“NIGHT”
:
„
DAY
”
period
Heating
circuits
The preset temperature is
set as "DAY"
.
DHW tank
DHW tank is loaded up to
DHW preset temperature
.
DHW
circulation
DHW
circulating
pump
transports heat from the
DHW tank to a distant DHW
receivers.
Main heat
source
Active.
„NIGHT” period
Heating
circuits
The preset temperature is
set as "NIGHT"
.
DHW tank
DHW tank is switch off.
DHW
circulation
Circulating pump is switch
off.
Main heat
source
Blockade.
The time programs are inactive
when the heating circuits are
controlled by thermostats (with ON-
OFF contacts type). Then on the
thermostats the room preset
temperature is set and schedule,
which affects the individual heating
circuits.
Summer - winter
Outside the heating season the controller can
be switched to SUMMER mode. It enables to
switched off heating circuits such as radiation
or floor heating and maintain operation of
DHW tank loading function.
SUMMER mode can be activated manually in
the menu:
Summer/Winter
→
Summer mode = ON
SUMMER mode can be also activated
automatically. In order to do this, select:
Summer mode = AUTO
. The controller will
enter SUMMER mode when the external
temperature exceeds the
SUMMER activation
temperature
parameter. The controller will
deactivate SUMMER mode when the external
temperature
drops
below
SUMMER
deactivation temperature
parameter.
In SUMMER mode, all heat
receivers can be turned off, so
make sure that the heat source will
not overheat before switching it
on.
Automatic switching into SUMMER
mode is possible only when the
external temperature sensor is
connected.
Holiday planning
The controller is equipped with a function
enabling to plan holiday, i.e. days during
which the user is outside his home. The
function is activated in the menu:
Basic settings
→
Holiday out of house
Enter holiday start and end date and set the
Activation = ON
.
During these days heating circuits are turned
off. If frost protection mode is active, the frost
protection setpoint temperature is maintained
on the heating circuits. The DHW tank is not
charged.
Changing names
It is possible to change a default name of the
room thermostats and names of heating
circuits displayed in the controller, in the
menu:
Basic settings
→
Change name
Parental lock
It is possible to lock the touch screen against
children. Lock is activated in the menu:
Basic settings
→
Parental control
Lock is activated automatically after a set
inactivity time. In order to unlock the
controller, press the screen in any place and
hold it for 4s.
Screen brightness adjustment
Three screen brightness levels are available:
-
„Ed
ition
” –
screen brightness for editing
parameters,
-
„
DAY
” –
screen brightness between 06:00
–
22:00,
-
„
NIGHT
” –
screen brightness between
22:00
–
06:00.