80 - 104
Communication protocol
START
T1-T2-T3-T4 (transmission time of 3.5 bytes)
ADDR 02H
CMD 06H
High bit of writing data address
00H
Low bit of writing data address
04H
data content
13H
data content
88H
CRC CHK low bit
C5H
CRC CHK high bit
6EH
END
T1-T2-T3-T4 (transmission time of 3.5 bytes)
RTU slave response message (from the inverter to the master)
START
T1-T2-T3-T4 (transmission time of 3.5 bytes)
ADDR 02H
CMD 06H
High bit of writing data address
00H
Low bit of writing data address
04H
High bit of data content
13H
Low bit of data content
88H
CRC CHK low bit
C5H
CRC CHK high bit
6EH
END
T1-T2-T3-T4 (transmission time of 3.5 bytes)
Note:
section 7.3.1 and 7.3.2 mainly describe the command format, and the detailed application will be
mentioned in 7.3.3 with examples.
7.3.3 Command code 08H for diagnosis
Meaning of sub-function codes
Sub-function Code
Description
0000
Return to inquire information data
For example: The inquiry information string is the same as the response information string when the loop
detection to address 01H of driver is carried out.
The RTU request command is:
START
T1-T2-T3-T4 (transmission time of 3.5 bytes)
ADDR 01H
CMD 08H
High byte of sub-function code
00H
Low byte of sub-function code
00H
High byte of data content
12H
Low byte of data content
ABH