Chapter 5: Troubleshooting
236
Status signalling
08046
Timeout of
startup
sequence - No
antenna or
antenna
temperature
too low
The start-up
sequence of the
terminal has timed
out because:
•
the antenna is
not properly
connected, or
•
the antenna
temperature is
too low to start
up.
Check that the
antenna cable is
properly connected
at both ends.
08048
All PoE ports
except port 1
are shut down
due to high
temperature
The temperature in
the terminal is too
high. All PoE ports
except port 1 are
shut down to reduce
the temperature.
Move the terminal
to a cooler location,
or avoid using PoE
on port 2-4.
08049
Data rate
reduction due
to high
temperature
The bit rate of the
data channel is
reduced because
the temperature is
too high.
Move the terminal
to a cooler location
0804B
Illegal
combination of
antenna and
terminal
You are not using
the right
combination of
antenna and
terminal.
Only use the
antenna(s) intended
for use with your
terminal.
ID
Event Text
Explanation
Remedy
Содержание 250 FleetBroadband
Страница 1: ...SAILOR 500 250 FleetBroadband Including 19 Rack Version USER MANUAL...
Страница 2: ......
Страница 12: ...x...
Страница 16: ...Table of Contents xiv...
Страница 34: ...Chapter 1 Introduction 18 Services and interfaces...
Страница 94: ...Chapter 3 Operating the system 78 Using the Thrane IP handset...
Страница 268: ......
Страница 270: ......
Страница 272: ......
Страница 274: ......
Страница 287: ......
Страница 288: ...98 125645 G info thrane com thrane com...