Chapter 5: Troubleshooting
232
Status signalling
0800B
PoE
Overvoltage
protection is
activated
Overvoltage is
detected in the
terminal. The
terminal will be
shut down in 10
minutes.
Do not use the
terminal.
Contact your
distributor.
0800D
Antenna
Overvoltage
protection is
activated
Overvoltage is
detected in the
antenna. The
terminal will be
shut down in 10
minutes.
Do not use the
terminal.
Contact your
distributor.
08010
Undervoltage
has been
detected
The input voltage
has dropped below
an acceptable level.
The terminal will be
shut down in 10
seconds if the
situation persists.
Ensure a stable
power supply to the
terminal.
0801B
Lost
connection to
the GPS
receiver
Communication
with the GPS
receiver in the
antenna is lost.
Contact your
distributor if the
warning persists.
0801D
Uploading
firmware to
antenna
New firmware is
being uploaded to
the antenna.
The Event will be
cleared when
upload has finished.
Contact your
distributor if the
Event is not cleared
within 5 minutes.
ID
Event Text
Explanation
Remedy
Содержание 250 FleetBroadband
Страница 1: ...SAILOR 500 250 FleetBroadband Including 19 Rack Version USER MANUAL...
Страница 2: ......
Страница 12: ...x...
Страница 16: ...Table of Contents xiv...
Страница 34: ...Chapter 1 Introduction 18 Services and interfaces...
Страница 94: ...Chapter 3 Operating the system 78 Using the Thrane IP handset...
Страница 268: ......
Страница 270: ......
Страница 272: ......
Страница 274: ......
Страница 287: ......
Страница 288: ...98 125645 G info thrane com thrane com...